-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (116 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 12 July, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe
Authors:
NEXT Collaboration,
N. Byrnes,
E. Dey,
F. W. Foss,
B. J. P. Jones,
R. Madigan,
A. McDonald,
R. L. Miller,
K. E. Navarro,
L. R. Norman,
D. R. Nygren,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
J. E. Barcelon,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa
, et al. (90 additional authors not shown)
Abstract:
The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at t…
▽ More
The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.
△ Less
Submitted 20 May, 2024;
originally announced June 2024.
-
Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers
Authors:
T. Contreras,
B. Palmeiro,
H. Almazán,
A. Para,
G. Martínez-Lema,
R. Guenette,
C. Adams,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel,
A. Castillo
, et al. (85 additional authors not shown)
Abstract:
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand th…
▽ More
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Supernova Electron-Neutrino Interactions with Xenon in the nEXO Detector
Authors:
nEXO Collaboration,
S. Hedges,
S. Al Kharusi,
E. Angelico,
J. P. Brodsky,
G. Richardson,
S. Wilde,
A. Amy,
A. Anker,
I. J. Arnquist,
P. Arsenault,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao
, et al. (121 additional authors not shown)
Abstract:
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theor…
▽ More
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5 to 8 kpc from earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions
Authors:
NEXT Collaboration,
K. Mistry,
L. Rogers,
B. J. P. Jones,
B. Munson,
L. Norman,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel
, et al. (85 additional authors not shown)
Abstract:
NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondar…
▽ More
NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.
△ Less
Submitted 21 December, 2023; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector
Authors:
J. Haefner,
K. E. Navarro,
R. Guenette,
B. J. P. Jones,
A. Tripathi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. BenllochRodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel,
J. V. Carrión
, et al. (86 additional authors not shown)
Abstract:
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the dr…
▽ More
Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from $^{83\mathrm{m}}$Kr calibration electron captures ($E\sim45$keV), the position of origin of low-energy events is determined to $2~$cm precision with bias $< 1$mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E$\geq$1.5MeV), yielding a precision of 3cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q$_{ββ}$ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Evaluation of SNOLAB background mitigation procedures through the use of an ICP-MS based dust monitoring methodology
Authors:
M. L. di Vacri,
S. Scorza,
A. French,
N. D. Rocco,
T. D. Schlieder,
I. J. Arnquist,
E. W. Hoppe,
J. Hall
Abstract:
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models…
▽ More
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. In this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB, and informs dust backgrounds during laboratory activities. Fallout rates of major constituent of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. A ca. two order of magnitude increase in stable Pb fallout rate was determined in an experimental area during activities involving handling of Pb bricks. Increased K-40, Th-232, and U-238 fallout rates were measured in clean experimental areas during activities generating particulate.
△ Less
Submitted 23 August, 2023;
originally announced August 2023.
-
Majorana Demonstrator Data Release for AI/ML Applications
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
N. Fuad,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (35 additional authors not shown)
Abstract:
The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificia…
▽ More
The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificial Intelligence (AI) and Machine Learning (ML) algorithms upon our data. This document is structured as follows. Section I provides an overview of the dataset's content and format; Section II outlines the location of this dataset and the method for accessing it; Section III presents the NPML Machine Learning Challenge associated with this dataset; Section IV contains a disclaimer from the Majorana collaboration regarding the use of this dataset; Appendix A contains technical details of this data release. Please direct questions about the material provided within this release to liaobo77@ucsd.edu (A. Li).
△ Less
Submitted 14 September, 2023; v1 submitted 21 August, 2023;
originally announced August 2023.
-
Energy Calibration of Germanium Detectors for the MAJORANA DEMONSTRATOR
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (31 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay ($0νββ$) in the $^{76}$Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a $^{228}$Th line source for 1 to 2 hours. The energy scal…
▽ More
The MAJORANA DEMONSTRATOR was a search for neutrinoless double-beta decay ($0νββ$) in the $^{76}$Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a $^{228}$Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.
△ Less
Submitted 3 August, 2023; v1 submitted 14 June, 2023;
originally announced June 2023.
-
Constraints on the decay of $^{180m}$Ta
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (34 additional authors not shown)
Abstract:
$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β…
▽ More
$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β$ and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the MAJORANA DEMONSTRATOR, an experimental search for the neutrinoless double-beta decay of $^{76}$Ge using an array of high-purity germanium detectors, to search for the decay of $^{180m}$Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the $^{180m}$Ta half-life on the different decay channels. With new limits up to 1.5 x $10^{19}$ years, we improved existing limits by one to two orders of magnitude. This result is the most sensitive search for a single $β$ and electron capture decay ever achieved.
△ Less
Submitted 2 June, 2023;
originally announced June 2023.
-
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián
, et al. (90 additional authors not shown)
Abstract:
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means o…
▽ More
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0ν}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.
△ Less
Submitted 22 September, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
NEXT-CRAB-0: A High Pressure Gaseous Xenon Time Projection Chamber with a Direct VUV Camera Based Readout
Authors:
NEXT Collaboration,
N. K. Byrnes,
I. Parmaksiz,
C. Adams,
J. Asaadi,
J Baeza-Rubio,
K. Bailey,
E. Church,
D. González-Díaz,
A. Higley,
B. J. P. Jones,
K. Mistry,
I. A. Moya,
D. R. Nygren,
P. Oyedele,
L. Rogers,
K. Stogsdill,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo
, et al. (94 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay ($0νββ$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to $0νββ$ searches due to their intrinsically precise energy resolution and topological event identification capabilities. Scalability to ton- and multi-ton masses requires read…
▽ More
The search for neutrinoless double beta decay ($0νββ$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to $0νββ$ searches due to their intrinsically precise energy resolution and topological event identification capabilities. Scalability to ton- and multi-ton masses requires readout of large-area electroluminescent regions with fine spatial resolution, low radiogenic backgrounds, and a scalable data acquisition system. This paper presents a detector prototype that records event topology in an electroluminescent xenon gas TPC via VUV image-intensified cameras. This enables an extendable readout of large tracking planes with commercial devices that reside almost entirely outside of the active medium.Following further development in intermediate scale demonstrators, this technique may represent a novel and enlargeable method for topological event imaging in $0νββ$.
△ Less
Submitted 3 August, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Ultra-low radioactivity flexible printed cables
Authors:
Isaac J. Arnquist,
Maria Laura di Vacri,
Nicole Rocco,
Richard Saldanha,
Tyler Schlieder,
Raj Patel,
Jay Patil,
Mario Perez,
Harshad Uka
Abstract:
Flexible printed cables and circuitry based on copper-polyimide materials are widely used in experiments looking for rare events due to their unique electrical and mechanical characteristics. However, past studies have found copper-polyimide flexible cables to contain 400-4700 pg $^{238}$U/g, 16-3700 pg $^{232}$Th/g, and 170-2100 ng $^{nat}$K/g, which can be a significant source of radioactive bac…
▽ More
Flexible printed cables and circuitry based on copper-polyimide materials are widely used in experiments looking for rare events due to their unique electrical and mechanical characteristics. However, past studies have found copper-polyimide flexible cables to contain 400-4700 pg $^{238}$U/g, 16-3700 pg $^{232}$Th/g, and 170-2100 ng $^{nat}$K/g, which can be a significant source of radioactive background for many current and next-generation ultralow background detectors. This study presents a comprehensive investigation into the fabrication process of copper-polyimide flexible cables and the development of custom low radioactivity cables for use in rare-event physics applications. A methodical step-by-step approach was developed and informed by ultrasensitive assay to determine the radiopurity in the starting materials and identify the contaminating production steps in the cable fabrication process. Radiopure material alternatives were identified, and cleaner production processes and treatments were developed to significantly reduce the imparted contamination. Through the newly developed radiopure fabrication process, fully-functioning cables were produced with radiocontaminant concentrations of 20-31 pg $^{238}$U/g, 12-13 pg $^{232}$Th/g, and 40-550 ng $^{nat}$K/g, which is significantly cleaner than cables from previous work and sufficiently radiopure for current and next-generation detectors. This approach, employing witness samples to investigate each step of the fabrication process, can hopefully serve as a template for investigating radiocontaminants in other material production processes.
△ Less
Submitted 20 March, 2023;
originally announced March 2023.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
A Compact Dication Source for Ba$^{2+}$ Tagging and Heavy Metal Ion Sensor Development
Authors:
K. E. Navarro,
B. J. P. Jones,
J. Baeza-Rubio,
M. Boyd,
A. A. Denisenko,
F. W. Foss,
S. Giri,
R. Miller,
D. R. Nygren,
M. R. Tiscareno,
F. J. Samaniego,
K. Stogsdill,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges
, et al. (85 additional authors not shown)
Abstract:
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the…
▽ More
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean $\mathrm{Ba^{2+}}$ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb$^{2+}$ and Cd$^{2+}$ also demonstrated for this purpose.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley,
H. Coombes
, et al. (108 additional authors not shown)
Abstract:
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nuc…
▽ More
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 17 February, 2023;
originally announced February 2023.
-
Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers
Authors:
E. Adams,
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas,
A. García Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. Jin
, et al. (30 additional authors not shown)
Abstract:
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been dev…
▽ More
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.
△ Less
Submitted 21 January, 2023;
originally announced January 2023.
-
Neutrinoless Double Beta Decay
Authors:
C. Adams,
K. Alfonso,
C. Andreoiu,
E. Angelico,
I. J. Arnquist,
J. A. A. Asaadi,
F. T. Avignone,
S. N. Axani,
A. S. Barabash,
P. S. Barbeau,
L. Baudis,
F. Bellini,
M. Beretta,
T. Bhatta,
V. Biancacci,
M. Biassoni,
E. Bossio,
P. A. Breur,
J. P. Brodsky,
C. Brofferio,
E. Brown,
R. Brugnera,
T. Brunner,
N. Burlac,
E. Caden
, et al. (207 additional authors not shown)
Abstract:
This White Paper, prepared for the Fundamental Symmetries, Neutrons, and Neutrinos Town Meeting related to the 2023 Nuclear Physics Long Range Plan, makes the case for double beta decay as a critical component of the future nuclear physics program. The major experimental collaborations and many theorists have endorsed this white paper.
This White Paper, prepared for the Fundamental Symmetries, Neutrons, and Neutrinos Town Meeting related to the 2023 Nuclear Physics Long Range Plan, makes the case for double beta decay as a critical component of the future nuclear physics program. The major experimental collaborations and many theorists have endorsed this white paper.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness
Authors:
J. Haefner,
A. Fahs,
J. Ho,
C. Stanford,
R. Guenette,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church
, et al. (78 additional authors not shown)
Abstract:
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm,…
▽ More
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm, and 450~nm. The results show that TPB-coated PTFE has a reflectance of approximately 92\% for thicknesses ranging from 5~mm to 10~mm at 450~nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5~mm to 10~mm does not affect significantly the light response at 128~nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10~mm can be used in particle physics detectors without compromising the light signal.
△ Less
Submitted 10 January, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Modeling Backgrounds for the MAJORANA DEMONSTRATOR
Authors:
C. R. Haufe,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay ($0νββ$) experiment containing $\sim$30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and $\sim$14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prio…
▽ More
The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay ($0νββ$) experiment containing $\sim$30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and $\sim$14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the $0νββ$ Q-value, 15.7 $\pm$ 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.
△ Less
Submitted 11 January, 2023; v1 submitted 21 September, 2022;
originally announced September 2022.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Charge Trapping and Energy Performance of the MAJORANA DEMONSTRATOR
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (33 additional authors not shown)
Abstract:
P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the MAJORANA DEMONSTRATOR, a neutrinoless double-beta decay experiment deploying PPC detectors enriched in $^{76}$Ge, has led to several novel improvements in…
▽ More
P-type point contact (PPC) high-purity germanium detectors are an important technology in astroparticle and nuclear physics due to their superb energy resolution, low noise, and pulse shape discrimination capabilities. Analysis of data from the MAJORANA DEMONSTRATOR, a neutrinoless double-beta decay experiment deploying PPC detectors enriched in $^{76}$Ge, has led to several novel improvements in the analysis of PPC signals. In this work we discuss charge trapping in PPC detectors and its effect on energy resolution. Small dislocations or impurities in the crystal lattice result in trapping of charge carriers from an ionization event of interest, attenuating the signal and degrading the measured energy. We present a modified digital pole-zero correction to the signal energy estimation that counters the effects of charge trapping and improves the energy resolution of the MAJORANA DEMONSTRATOR by approximately 30% to around 2.4 keV FWHM at 2039 keV, the $^{76}$Ge $Q$-value. An alternative approach achieving similar resolution enhancement is also presented.
△ Less
Submitted 26 April, 2023; v1 submitted 1 August, 2022;
originally announced August 2022.
-
Mass spectrometric investigations into 3D printed parts to assess radiopurity as ultralow background materials for rare event physics detectors
Authors:
Amanda D. French,
Sonia Alcantar Anguiano,
Mary Bliss,
Josef Christ,
Maria Laura di Vacri,
Rebecca Erikson,
Khadouja Harouaka,
Eric W. Hoppe,
Jay W. Grate,
Isaac J. Arnquist
Abstract:
New data are reported for polyvinylidene fluoride (PVDF), polyphenylene sulfide (PPS), and two forms of polyetherimide (PEI, branded ULTEM 1010 and 9085). Data for starting filaments and both simple and complex printed parts are reported. PVDF filaments and simple printed beads, were found to have values of approximately 30 and 50 ppt for Th-232 and U-238, respectively, while a more complex spring…
▽ More
New data are reported for polyvinylidene fluoride (PVDF), polyphenylene sulfide (PPS), and two forms of polyetherimide (PEI, branded ULTEM 1010 and 9085). Data for starting filaments and both simple and complex printed parts are reported. PVDF filaments and simple printed beads, were found to have values of approximately 30 and 50 ppt for Th-232 and U-238, respectively, while a more complex spring clip part had slightly elevated Th-232 levels of 65 ppt, with U-238 remaining at 50 ppt. PPS filament was found to have concentrations of 270 and 710 ppt for Th-232 and U-238, respectively, and were not chosen to be printed as those levels were already higher than other material options. ULTEM 1010 filaments and printed complex spring clip parts were found to have concentrations of around 5 and 7 ppt for Th-232 and U-238, respectively, illustrating no significant contamination from the printing process. ULTEM 9085 filaments were found to have concentrations of around 9 and 5 ppt for Th-232 and U-238, respectively, while the printed complex spring clip part was found to have slightly elevated concentrations of 25 and 7 ppt for Th-232 and U-238, respectively. These results were all obtained using a novel dry ashing method in crucibles constructed of ultralow background electroformed copper or, when applicable, microwave-assisted wet ashing digestion. Samples and process blanks were spiked with Th-229 and U-233 as internal standards prior to dry/wet ashing and determinations were made by inductively coupled plasma mass spectrometry (ICP-MS). In order to maintain high radiopurity levels, pre-cleaning the filaments before printing and post-cleaning the parts is recommended, although the printing process itself has shown to contribute very minute amounts of radiocontaminants.
△ Less
Submitted 27 July, 2022;
originally announced July 2022.
-
Interpretable Boosted Decision Tree Analysis for the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y -D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. Henning
, et al. (30 additional authors not shown)
Abstract:
The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logi…
▽ More
The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.
△ Less
Submitted 15 February, 2023; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Development of silicon interposer: towards an ultralow radioactivity background photodetector system
Authors:
Haibo Yang,
Qidong Wang,
Guofu Cao,
Kali M. Melby,
Khadouja Harouaka,
Isaac J. Arnquist,
Fengwei Dai,
Liqiang Cao,
Liangjian Wen
Abstract:
It is of great importance to develop a photodetector system with an ultralow radioactivity background in rare event searches. Silicon photomultipliers (SiPMs) and application-specific integrated circuits (ASICs) are two ideal candidates for low background photosensors and readout electronics, respectively, because they are mainly composed of silicon, which can achieve good radio-purity without con…
▽ More
It is of great importance to develop a photodetector system with an ultralow radioactivity background in rare event searches. Silicon photomultipliers (SiPMs) and application-specific integrated circuits (ASICs) are two ideal candidates for low background photosensors and readout electronics, respectively, because they are mainly composed of silicon, which can achieve good radio-purity without considerable extra effort. However, interposers, used to provide mechanical support and signal routes between the photosensor and the electronics, are a bottleneck in building ultralow background photodetectors. Silicon and quartz are two candidates to construct the low background interposer because of their good radio-purity; nevertheless, it is non-trivial to produce through silicon vias (TSV) or through quartz vias (TQV) on the large area silicon or quartz wafer. In this work, based on double-sided TSV interconnect technology, we developed the first prototype of a silicon interposer with a size of 10~cm$\times$10~cm and a thickness of 320~$μ$m. The electrical properties of the interposer are carefully evaluated at room temperature, and its performance is also examined at -110~$^\circ$C with an integrated SiPM on the interposer. The testing results reveal quite promising performance of the prototype, and the single photoelectron signals can be clearly observed from the SiPM. The features of the observed signals are comparable with those from the SiPM mounted on a normal FR4-based PCB. Based on the success of the silicon interposer prototype, we started the follow-up studies that aimed to further improve the performance and yield of the silicon interposer, and eventually to provide a solution for building an ultralow background photodetector system.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double-$β$ Decay in $^{76}$Ge
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (35 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a…
▽ More
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a world-leading energy resolution of 2.52 keV FWHM at the 2039 keV $Q_{ββ}$ (0.12\%), we set a half-life limit of $0νββ$ in $^{76}$Ge at $T_{1/2}>8.3\times10^{25}$ yr (90\% C.L.). This provides a range of upper limits on $m_{ββ}$ of $(113-269)$ meV (90\% C.L.), depending on the choice of nuclear matrix elements.
△ Less
Submitted 10 February, 2023; v1 submitted 15 July, 2022;
originally announced July 2022.
-
Exotic dark matter search with the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (34 additional authors not shown)
Abstract:
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report ne…
▽ More
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report new limits on fermionic dark matter absorption ($χ+ A \rightarrow ν+ A$) and sub-GeV DM-nucleus 3$\rightarrow$2 scattering ($χ+ χ+ A \rightarrow φ+ A$), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the 1--100 keV low energy region of a 37.5 kg-y exposure collected by the Demonstrator between May 2016 and Nov. 2019, using a set of $^{76}$Ge-enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation.
△ Less
Submitted 21 June, 2022;
originally announced June 2022.
-
Exploration of Methods to Remove Implanted $^{210}$Pb and $^{210}$Po Contamination from Silicon Surfaces
Authors:
Isaac J. Arnquist,
Raymond Bunker,
Zdenek Dohnalek,
Runze Ma,
Nicolas Uhnak
Abstract:
Radioactive contaminants on the surfaces of detector components can be a problematic source of background events for physics experiments searching for rare processes. Exposure to radon is a specific concern because it can result in the relatively long-lived $^{210}$Pb (and progeny) being implanted to significant subsurface depths such that removal is challenging. In this article we present results…
▽ More
Radioactive contaminants on the surfaces of detector components can be a problematic source of background events for physics experiments searching for rare processes. Exposure to radon is a specific concern because it can result in the relatively long-lived $^{210}$Pb (and progeny) being implanted to significant subsurface depths such that removal is challenging. In this article we present results from a broad exploration of cleaning treatments to remove implanted $^{210}$Pb and $^{210}$Po contamination from silicon, which is an important material used in several rare-event searches. We demonstrate for the first time that heat treatments ("baking") can effectively mitigate such surface contamination, with the results of a 1200 $^{\circ}$C bake consistent with perfect removal. We also report results using wet-chemistry and plasma-based methods, which show that etching can be highly effective provided the etch depth is sufficiently aggressive. Our survey of cleaning methods suggests consideration of multiple approaches during the different phases of detector construction to enable greater flexibility for efficient removal of $^{210}$Pb and $^{210}$Po surface contamination
△ Less
Submitted 13 June, 2022;
originally announced June 2022.
-
Search for solar axions via axion-photon coupling with the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (33 additional authors not shown)
Abstract:
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium dete…
▽ More
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium detectors using a 33 kg-yr exposure collected between Jan. 2017 and Nov. 2019. A temporal-energy analysis gives a new limit on the axion-photon coupling as $g_{aγ}<1.45\times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axions with mass up to 100 eV/$c^2$. This improves laboratory-based limits between about 1 eV/$c^2$ and 100 eV/$c^2$.
△ Less
Submitted 22 August, 2022; v1 submitted 12 June, 2022;
originally announced June 2022.
-
Effective Field Theory Analysis of CDMSlite Run 2 Data
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (105 additional authors not shown)
Abstract:
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected back…
▽ More
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
F. Girard,
G. Giroux,
O. Harris,
E. W. Hoppe,
C. M. Jackson,
M. Jin,
C. B. Krauss
, et al. (32 additional authors not shown)
Abstract:
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct…
▽ More
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.
△ Less
Submitted 7 November, 2022; v1 submitted 11 May, 2022;
originally announced May 2022.
-
Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. Jin
, et al. (30 additional authors not shown)
Abstract:
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact…
▽ More
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.
△ Less
Submitted 21 April, 2022;
originally announced April 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimate…
▽ More
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $γ$-rays emitted from the excited $^{16}$O states that are populated when the incoming $α$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($α,n$)-reactions in future double-beta decay search efforts.
△ Less
Submitted 11 July, 2022; v1 submitted 27 March, 2022;
originally announced March 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Charge conservation and the Pauli exclusion principle (PEP) result from fundamental symmetries in the Standard Model, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. In this work we consider three models for violation of these processes which would produce detectable ionization in the high-purity germanium detectors of…
▽ More
Charge conservation and the Pauli exclusion principle (PEP) result from fundamental symmetries in the Standard Model, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. In this work we consider three models for violation of these processes which would produce detectable ionization in the high-purity germanium detectors of the Majorana Demonstrator. Using a 37.5 kg-yr exposure, we report a new lower limit on the electron mean lifetime of $τ_e > 3.2 \times 10^{25}$ yr (90\% CL), the best result for this decay channel ($e \rightarrow ν_e \overline{ν_e} ν_e$ or more generally $e \rightarrow \mathrm{invisibles}$) in more than two decades. We also present searches for two types of violation of the PEP, setting new limits on the probability of two electrons forming a symmetric quantum state. Using our $^{228}$Th calibration data set, which introduces electrons new to the system through electron-positron pair production, we obtain a world-leading model-independent limit for a terrestrial experiment of $β^2/2 < 1.0 \times 10^{-3}$ (99.7\% CL). Our 37.5 kg-yr exposure is also used to search for a process where an electron in an atomic system spontaneously violates the PEP, resulting in a model-dependent upper limit of $β^2/2 < 1.0 \times 10^{-48}$ (90\% CL).
△ Less
Submitted 11 January, 2023; v1 submitted 3 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Neutral Bremsstrahlung emission in xenon unveiled
Authors:
C. A. O. Henriques,
P. Amedo,
J. M. R. Teixeira,
D. Gonzalez-Diaz,
C. D. R. Azevedo,
A. Para,
J. Martin-Albo,
A. Saa Hernandez,
J. J. Gomez-Cadenas,
D. R. Nygren,
C. M. B. Monteiro,
C. Adams,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodriguez,
F. I. G. M. Borges,
N. Byrnes,
S. Carcel,
J. V. Carrion,
S. Cebrian,
E. Church,
C. A. N. Conde
, et al. (68 additional authors not shown)
Abstract:
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that has been postulated to exist in xenon that has been largely overlooked. For photon emission below 1000…
▽ More
We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White TPC and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that has been postulated to exist in xenon that has been largely overlooked. For photon emission below 1000 nm, the NBrS yield increases from about 10$^{-2}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at pressure-reduced electric field values of 50 V cm$^{-1}$ bar$^{-1}$ to above 3$\times$10$^{-1}$ photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$ at 500 V cm$^{-1}$ bar$^{-1}$. Above 1.5 kV cm$^{-1}$ bar$^{-1}$, values that are typically employed for electroluminescence, it is estimated that NBrS is present with an intensity around 1 photon/e$^{-}$ cm$^{-1}$ bar$^{-1}$, which is about two orders of magnitude lower than conventional, excimer-based electroluminescence. Despite being fainter than its excimeric counterpart, our calculations reveal that NBrS causes luminous backgrounds that can interfere, in either gas or liquid phase, with the ability to distinguish and/or to precisely measure low primary-scintillation signals (S1). In particular, we show this to be the case in the "buffer" and "veto" regions, where keeping the electric field below the electroluminescence (EL) threshold will not suffice to extinguish secondary scintillation. The electric field in these regions should be chosen carefully to avoid intolerable levels of NBrS emission. Furthermore, we show that this new source of light emission opens up a viable path towards obtaining S2 signals for discrimination purposes in future single-phase liquid TPCs for neutrino and dark matter physics, with estimated yields up to 20-50 photons/e$^{-}$ cm$^{-1}$.
△ Less
Submitted 13 May, 2022; v1 submitted 5 February, 2022;
originally announced February 2022.
-
Search for Spontaneous Radiation from Wavefunction Collapse in the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. Henning
, et al. (29 additional authors not shown)
Abstract:
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in $^{76}\mathrm{Ge}$) array of $p$-type, point-contact germanium detectors. With its unprecedented energy resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the co…
▽ More
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in $^{76}\mathrm{Ge}$) array of $p$-type, point-contact germanium detectors. With its unprecedented energy resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the continuous spontaneous localization (CSL) model, one of the mathematically well-motivated wave function collapse models aimed at solving the long-standing unresolved quantum mechanical measurement problem. While the CSL predicts the existence of a detectable radiation signature in the x-ray domain, we find no evidence of such radiation in the 19--100 keV range in a 37.5 kg-y enriched germanium exposure collected between December 31, 2015, and November 27, 2019, with the Demonstrator. We explored both the non-mass-proportional (n-m-p) and the mass-proportional (m-p) versions of the CSL with two different assumptions: that only the quasifree electrons can emit the x-ray radiation and that the nucleus can coherently emit an amplified radiation. In all cases, we set the most stringent upper limit to date for the white CSL model on the collapse rate, $λ$, providing a factor of 40--100 improvement in sensitivity over comparable searches. Our limit is the most stringent for large parts of the allowed parameter space. If the result is interpreted in terms of the Diòsi-Penrose gravitational wave function collapse model, the lower bound with a 95% confidence level is almost an order of magnitude improvement over the previous best limit.
△ Less
Submitted 12 June, 2023; v1 submitted 2 February, 2022;
originally announced February 2022.
-
Ba$^{2+}$ ion trapping by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector
Authors:
P. Herrero-Gómez,
J. P. Calupitan,
M. Ilyn,
A. Berdonces-Layunta,
T. Wang,
D. G. de Oteyza,
M. Corso,
R. González-Moreno,
I. Rivilla,
B. Aparicio,
A. I. Aranburu,
Z. Freixa,
F. Monrabal,
F. P. Cossío,
J. J. Gómez-Cadenas,
C. Rogero,
C. Adams,
H. Almazán,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester
, et al. (90 additional authors not shown)
Abstract:
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay…
▽ More
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay ${}^{136}\mathrm{Xe} \rightarrow {}^{136}$Ba$^{+2}+ 2 e + (2 ν)$ in a high pressure gas experiment, could lead to a virtually background free experiment. To identify these \Bapp, chemical sensors are being explored as a key tool by the NEXT collaboration . Although used in many fields, the application of such chemosensors to the field of particle physics is totally novel and requires experimental demonstration of their suitability in the ultra-dry environment of a xenon gas chamber. Here we use a combination of complementary surface science techniques to unambiguously show that Ba$^{+2}$ ions can be trapped (chelated) in vacuum by an organic molecule, the so-called fluorescent bicolour indicator (FBI) (one of the chemosensors developed by NEXT), immobilized on a surface. We unravel the ion capture mechanism once the molecules are immobilised on Au(111) surface and explain the origin of the emission fluorescence shift associated to the trapping of different ions. Moreover, we prove that chelation also takes place on a technologically relevant substrate, as such, demonstrating the feasibility of using FBI indicators as building blocks of a Ba$^{+2}$ detector.
△ Less
Submitted 22 January, 2022;
originally announced January 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
Measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras
, et al. (85 additional authors not shown)
Abstract:
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-…
▽ More
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of $2.34^{+0.80}_{-0.46}\textrm{(stat)}^{+0.30}_{-0.17}\textrm{(sys)}\times10^{21}~\textrm{yr}$ is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double beta decay searches.
△ Less
Submitted 11 May, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
Signatures of muonic activation in the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
T. R. Edwards,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground.…
▽ More
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10$^{28}$ years half-life with background rates of 10$^{-5}$cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data is used to search for decay signatures of meta-stable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations, and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in $^{76}$Ge.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers
Authors:
NEXT Collaboration,
B. J. P. Jones,
A. Raymond,
K. Woodruff,
N. Byrnes,
A. A. Denisenko,
F. W. Foss,
K. Navarro,
D. R. Nygren,
T. T. Vuong,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
S. Cárcel
, et al. (85 additional authors not shown)
Abstract:
Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and…
▽ More
Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques.
△ Less
Submitted 29 September, 2021; v1 submitted 8 September, 2021;
originally announced September 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution
Authors:
A. Simón,
Y. Ifergan,
A. B. Redwine,
R. Weiss-Babai,
L. Arazi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
F. P. Cossío,
A. A. Denisenko
, et al. (78 additional authors not shown)
Abstract:
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of d…
▽ More
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~5 when reconstructing electron-positron pairs in the $^{208}$Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV $e^-e^+$ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.
△ Less
Submitted 21 May, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.