-
Search for solar axions by Primakoff effect with the full dataset of the CDEX-1B Experiment
Authors:
L. T. Yang,
S. K. Liu,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
J. R. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (61 additional authors not shown)
Abstract:
We present the first limit on $g_{Aγ}$ coupling constant using the Bragg-Primakoff conversion based on an exposure of 1107.5 kg days of data from the CDEX-1B experiment at the China Jinping Underground Laboratory. The data are consistent with the null signal hypothesis, and no excess signals are observed. Limits of the coupling $g_{Aγ}<2.08\times10^{-9}$ GeV$^{-1}$ (95\% C.L.) are derived for axio…
▽ More
We present the first limit on $g_{Aγ}$ coupling constant using the Bragg-Primakoff conversion based on an exposure of 1107.5 kg days of data from the CDEX-1B experiment at the China Jinping Underground Laboratory. The data are consistent with the null signal hypothesis, and no excess signals are observed. Limits of the coupling $g_{Aγ}<2.08\times10^{-9}$ GeV$^{-1}$ (95\% C.L.) are derived for axions with mass up to 100 eV/$c^2$. Within the hadronic model of KSVZ, our results exclude axion mass $>5.3~\rm{eV}/c^2$ at 95\% C.L.
△ Less
Submitted 12 May, 2024;
originally announced May 2024.
-
First Search for Light Fermionic Dark Matter Absorption on Electrons Using Germanium Detector in CDEX-10 Experiment
Authors:
J. X. Liu,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
J. R. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (61 additional authors not shown)
Abstract:
We present the first results of the search for sub-MeV fermionic dark matter absorbed by electron targets of Germanium using the 205.4~kg$\cdot$day data collected by the CDEX-10 experiment, with the analysis threshold of 160~eVee. No significant dark matter (DM) signals over the background are observed. Results are presented as limits on the cross section of DM--electron interaction. We present ne…
▽ More
We present the first results of the search for sub-MeV fermionic dark matter absorbed by electron targets of Germanium using the 205.4~kg$\cdot$day data collected by the CDEX-10 experiment, with the analysis threshold of 160~eVee. No significant dark matter (DM) signals over the background are observed. Results are presented as limits on the cross section of DM--electron interaction. We present new constraints of cross section in the DM range of 0.1--10 keV/$c^2$ for vector and axial-vector interaction. The upper limit on the cross section is set to be $\rm 5.5\times10^{-46}~cm^2$ for vector interaction, and $\rm 1.8\times10^{-46}~cm^2$ for axial-vector interaction at DM mass of 5 keV/$c^2$.
△ Less
Submitted 15 April, 2024;
originally announced April 2024.
-
Constraints on the Blazar-Boosted Dark Matter from the CDEX-10 Experiment
Authors:
R. Xu,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
We report new constraints on light dark matter (DM) boosted by blazars using the 205.4 kg day data from the CDEX-10 experiment located at the China Jinping Underground Laboratory. Two representative blazars, TXS 0506+56 and BL Lacertae are studied. The results derived from TXS 0506+56 exclude DM-nucleon elastic scattering cross sections from $4.6\times 10^{-33}\ \rm cm^2$ to…
▽ More
We report new constraints on light dark matter (DM) boosted by blazars using the 205.4 kg day data from the CDEX-10 experiment located at the China Jinping Underground Laboratory. Two representative blazars, TXS 0506+56 and BL Lacertae are studied. The results derived from TXS 0506+56 exclude DM-nucleon elastic scattering cross sections from $4.6\times 10^{-33}\ \rm cm^2$ to $1\times10^{-26}\ \rm cm^2$ for DM masses between 10 keV and 1 GeV, and the results derived from BL Lacertae exclude DM-nucleon elastic scattering cross sections from $2.4\times 10^{-34}\ \rm cm^2$ to $1\times10^{-26}\ \rm cm^2$ for the same range of DM masses. The constraints correspond to the best sensitivities among solid-state detector experiments in the sub-MeV mass range.
△ Less
Submitted 29 March, 2024;
originally announced March 2024.
-
Probing Dark Matter Particles from Evaporating Primordial Black Holes via Electron Scattering in the CDEX-10 Experiment
Authors:
Z. H. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
Dark matter (DM) is a major constituent of the Universe. However, no definite evidence of DM particles (denoted as ``$χ$") has been found in DM direct detection (DD) experiments to date. There is a novel concept that detecting $χ$ from evaporating primordial black holes (PBHs). We search for $χ$ emitted from PBHs by investigating their interaction with target electrons. The examined PBH masses ran…
▽ More
Dark matter (DM) is a major constituent of the Universe. However, no definite evidence of DM particles (denoted as ``$χ$") has been found in DM direct detection (DD) experiments to date. There is a novel concept that detecting $χ$ from evaporating primordial black holes (PBHs). We search for $χ$ emitted from PBHs by investigating their interaction with target electrons. The examined PBH masses range from 1$\times$10$^{15}$ to 7$\times$10$^{16}$ g under the current limits of PBH abundance $f_{PBH}$. Using 205.4 kg$\cdot$day data obtained from the CDEX-10 experiment conducted in the China Jinping Underground Laboratory, we exclude the $χ$--electron ($χ$--$e$) elastic-scattering cross section $σ_{χe} \sim 5\times10^{-29}$ cm$^2$ for $χ$ with a mass $m_χ\lesssim$ 0.1 keV from our results. If ($m_χ$, $σ_{χe}$) can be determined in the future, DD experiments are expected to impose strong constraints on $f_{PBH}$ for large $M_{PBH}$s.
△ Less
Submitted 29 March, 2024;
originally announced March 2024.
-
Experimental Limits on Solar Reflected Dark Matter with a New Approach on Accelerated-Dark-Matter-Electron Analysis in Semiconductors
Authors:
Z. Y. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
Recently a dark matter-electron (DM-electron) paradigm has drawn much attention. Models beyond the standard halo model describing DM accelerated by high energy celestial bodies are under intense examination as well. In this Letter, a velocity components analysis (VCA) method dedicated to swift analysis of accelerated DM-electron interactions via semiconductor detectors is proposed and the first HP…
▽ More
Recently a dark matter-electron (DM-electron) paradigm has drawn much attention. Models beyond the standard halo model describing DM accelerated by high energy celestial bodies are under intense examination as well. In this Letter, a velocity components analysis (VCA) method dedicated to swift analysis of accelerated DM-electron interactions via semiconductor detectors is proposed and the first HPGe detector-based accelerated DM-electron analysis is realized. Utilizing the method, the first germanium based constraint on sub-GeV solar reflected DM-electron interaction is presented with the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment. In the heavy mediator scenario, our result excels in the mass range of 5$-$15 keV/$c^2$, achieving a 3 orders of magnitude improvement comparing with previous semiconductor experiments. In the light mediator scenario, the strongest laboratory constraint for DM lighter than 0.1 MeV/$c^2$ is presented. The result proves the feasibility and demonstrates the vast potential of the VCA technique in future accelerated DM-electron analyses with semiconductor detectors.
△ Less
Submitted 24 April, 2024; v1 submitted 26 September, 2023;
originally announced September 2023.
-
Virtual segmentation of a small contact HPGe detector: inference of hit positions of single-site events via pulse shape analysis
Authors:
W. H. Dai,
H. Ma,
Z. Zeng,
L. T. Yang,
Q. Yue,
J. P. Cheng
Abstract:
Exploring hit positions of recorded events can help to understand and suppress backgrounds in rare event searching experiments. In this study, we virtually segment a small contact P-type high purity germanium detector (HPGe) into two layers. Single-site events (SSEs) in each layer are selected by an algorithm based on two pulse shape parameters: the charge pulse drift time ($T_{Q}$) and current pu…
▽ More
Exploring hit positions of recorded events can help to understand and suppress backgrounds in rare event searching experiments. In this study, we virtually segment a small contact P-type high purity germanium detector (HPGe) into two layers. Single-site events (SSEs) in each layer are selected by an algorithm based on two pulse shape parameters: the charge pulse drift time ($T_{Q}$) and current pulse rise time ($T_{I}$). To determine the shapes and volumes of the two layers, a Th-228 source is placed at top and side positions to irradiate the detector. The double escape peak events from 2614.5 keV $γ$-ray are selected as typical SSEs, their numbers in the two layers are used to calculate the volumes and shapes of those layers. Considering the statistical and systematic uncertainties, the inner layer volume is evaluated to be 47.2\%$\pm$0.26(stat.)\%$\pm$0.22(sys.)\% of the total sensitive volume. We extend our analysis for SSEs in 1400-2100 keV, the spectra of inner layer events acquired from experimental data using the selection algorithm are in good agreement with those from the simulation. For sources outside the HPGe detector, the outer layer can act as a shielding for the inner layer. Selecting the inner layer as the analysis volume can reduce the externalbackground in the signal region of Ge-76 neutrinoless double beta (0$νββ$) decay. We use the Th-228 source to evaluate the background suppression power of the virtual segmentation. After performing the single and multi-site event discrimination, the event rate in the 0$νββ$ signal region can be further suppressed by 12\% by selecting the inner layer as the analysis volume. The virtual segmentation could be used to efficiently suppress surface background like electrons from Ar-42/K-42 decay in 0$νββ$ experiments using germanium detector immersed in liquid argon.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
Projected WIMP sensitivity of the CDEX-50 dark matter experiment
Authors:
X. P. Geng,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
H. Gong,
Q. J. Guo,
T. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. Jiang,
S. Karmakar,
H. B. Li
, et al. (59 additional authors not shown)
Abstract:
CDEX-50 is a next-generation project of the China Dark Matter Experiment (CDEX) that aims to search for dark matter using a 50-kg germanium detector array. This paper comprises a thorough summary of the CDEX-50 dark matter experiment, including an investigation of potential background sources and the development of a background model. Based on the baseline model, the projected sensitivity of weakl…
▽ More
CDEX-50 is a next-generation project of the China Dark Matter Experiment (CDEX) that aims to search for dark matter using a 50-kg germanium detector array. This paper comprises a thorough summary of the CDEX-50 dark matter experiment, including an investigation of potential background sources and the development of a background model. Based on the baseline model, the projected sensitivity of weakly interacting massive particle (WIMP) is also presented. The expected background level within the energy region of interest, set to 2--2.5 keVee, is $\sim$0.01 counts keVee$^{-1}$ kg$^{-1}$ day$^{-1}$. At 90\% confidence level, the expected sensitivity to spin-independent WIMP-nucleon couplings is estimated to reach a cross-section of 5.1 $\times$ 10$^{-45}$ cm$^{2}$ for a WIMP mass of 5 GeV/c$^{2}$ with an exposure objective of 150 kg$\cdot$year and an analysis threshold of 160 eVee. This science goal will correspond to the most sensitive results for WIMPs with a mass of 2.2--8 GeV/c$^{2}$.
△ Less
Submitted 4 July, 2024; v1 submitted 4 September, 2023;
originally announced September 2023.
-
Searching for $^{76}$Ge neutrinoless double beta decay with the CDEX-1B experiment
Authors:
B. T. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
We operated a p-type point contact high purity germanium (PPCGe) detector (CDEX-1B, 1.008 kg) in the China Jinping Underground Laboratory (CJPL) for 500.3 days to search for neutrinoless double beta ($0νββ$) decay of $^{76}$Ge. A total of 504.3 kg $\cdot$ day effective exposure data was accumulated. The anti-coincidence and the multi/single-site event (MSE/SSE) discrimination methods were used to…
▽ More
We operated a p-type point contact high purity germanium (PPCGe) detector (CDEX-1B, 1.008 kg) in the China Jinping Underground Laboratory (CJPL) for 500.3 days to search for neutrinoless double beta ($0νββ$) decay of $^{76}$Ge. A total of 504.3 kg $\cdot$ day effective exposure data was accumulated. The anti-coincidence and the multi/single-site event (MSE/SSE) discrimination methods were used to suppress the background in the energy region of interest (ROI, $1989-2089$ keV for this work) with a factor of 23. A background level of 0.33 counts/(keV $\cdot$ kg $\cdot$ yr) was achieved. The lower limit on the half life of $^{76}$Ge $0νββ$ decay was constrained as $T_{1/2}^{0ν}\ > \ {2.2}\times 10^{23}\ \rm yr\ (90\% \ C.L.)$, corresponding to the upper limits on the effective Majorana neutrino mass: $\langle m_{ββ}\rangle < 2.3-5.2\ \mathrm{eV}$.
△ Less
Submitted 8 May, 2023; v1 submitted 1 May, 2023;
originally announced May 2023.
-
Search for boosted keV-MeV light dark matter particles from evaporating primordial black holes at the CDEX-10 experiment
Authors:
Z. H. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
We present novel constraints on boosted light dark matter particles (denoted as ``$χ$'') from evaporating primordial black holes (PBHs) using 205.4 kg$\cdot$day data from the China Jinping Underground Laboratory's CDEX-10 p-type point contact germanium detector with a 160 eVee analysis threshold. $χ$ from PBHs with masses ranging from 1$\times$10$^{15}$ g to 7$\times$10$^{16}$ g are searched in th…
▽ More
We present novel constraints on boosted light dark matter particles (denoted as ``$χ$'') from evaporating primordial black holes (PBHs) using 205.4 kg$\cdot$day data from the China Jinping Underground Laboratory's CDEX-10 p-type point contact germanium detector with a 160 eVee analysis threshold. $χ$ from PBHs with masses ranging from 1$\times$10$^{15}$ g to 7$\times$10$^{16}$ g are searched in this work. In the presence of PBH abundance compatible with present bounds, our result excludes the $χ$-nucleon elastic-scattering cross section region from 3.4$\times$10$^{-32}$ cm$^{2}$ to 2.3$\times$10$^{-29}$ cm$^{2}$ for $χ$ of 1 keV to 24 MeV from PBHs with masses of 5$\times$10$^{15}$ g, as well as from 1.1$\times$10$^{-28}$ cm$^{2}$ to 7.6$\times$10$^{-28}$ cm$^{2}$ for $χ$ of 1 keV to 0.6 MeV from PBHs with masses of 7$\times$10$^{16}$ g. If the $χ$-nucleon elastic-scattering cross section can be determined in the future, the abundance of PBHs may be severely constrained by $χ$ evaporation. With the lower threshold (160 eVee) of the CDEX-10 experiment compared to the previously used experiments, this work allows for a better reach at soft spectra produced by heavier PBHs, which demonstrates the vast potential of such a technical route to pursue $χ$ from larger PBHs with a low threshold.
△ Less
Submitted 7 September, 2023; v1 submitted 14 November, 2022;
originally announced November 2022.
-
Search for exotic interactions of solar neutrinos in the CDEX-10 experiment
Authors:
X. P. Geng,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar,
H. B. Li
, et al. (60 additional authors not shown)
Abstract:
We investigate exotic neutrino interactions using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment at the China Jinping Underground Laboratory. New constraints on the mass and couplings of new gauge bosons are presented. Two nonstandard neutrino interactions are considered: a $U(1)_{B-L}$ gauge-boson-induced interaction between an active neutrino and electron/nucleus, and a dark-photon-i…
▽ More
We investigate exotic neutrino interactions using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment at the China Jinping Underground Laboratory. New constraints on the mass and couplings of new gauge bosons are presented. Two nonstandard neutrino interactions are considered: a $U(1)_{B-L}$ gauge-boson-induced interaction between an active neutrino and electron/nucleus, and a dark-photon-induced interaction between a sterile neutrino and electron/nucleus via kinetic mixing with a photon. This work probes an unexplored parameter space involving sterile neutrino coupling with a dark photon. New laboratory limits are derived on dark photon masses below $1~{\rm eV}/c^{2}$ at some benchmark values of $Δm_{41}^{2}$ and $g^{\prime2}{\rm{sin}}^{2}2θ_{14}$.
△ Less
Submitted 2 June, 2023; v1 submitted 4 October, 2022;
originally announced October 2022.
-
Exotic Dark Matter Search with CDEX-10 Experiment at China's Jinping Underground Laboratory
Authors:
W. H. Dai,
L. P. Jia,
H. Ma,
Q. Yue,
K. J. Kang,
Y. J. Li,
H. P. An,
Greeshma C.,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
S. Karmakar
, et al. (59 additional authors not shown)
Abstract:
A search for exotic dark matter (DM) in the sub-GeV mass range has been conducted using 205 kg$\cdot$day data taken from a p-type point contact germanium detector of CDEX-10 experiment at China Jinping underground laboratory. New low-mass dark matter searching channels, neutral current fermionic DM absorption ($χ+A\rightarrow ν+A$) and DM-nucleus 3$\rightarrow$2 scattering ($χ+χ+A\rightarrow φ+A$)…
▽ More
A search for exotic dark matter (DM) in the sub-GeV mass range has been conducted using 205 kg$\cdot$day data taken from a p-type point contact germanium detector of CDEX-10 experiment at China Jinping underground laboratory. New low-mass dark matter searching channels, neutral current fermionic DM absorption ($χ+A\rightarrow ν+A$) and DM-nucleus 3$\rightarrow$2 scattering ($χ+χ+A\rightarrow φ+A$), have been analyzed with an energy threshold of 160 eVee. No significant signal was found. Thus new limits on the DM-nucleon interaction cross section are set for both models at sub-GeV DM mass region. A cross section limit for the fermionic DM absorption is set to be $\rm 2.5\times 10^{-46} cm^2$(90\% C.L.) at DM mass of 10 MeV/c$^2$. For the DM-nucleus 3$\rightarrow$2 scattering scenario, limits are extended to DM mass of 5 MeV/c$^2$ and 14 MeV/c$^2$ for the massless dark photon and bound DM final state, respectively.
△ Less
Submitted 23 November, 2022; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Modeling the Charge Collection Efficiency in the Li-diffused Inactive Layer of a P-type Point-Contact Germanium Detector
Authors:
W. H. Dai,
H. Ma,
Q. Yue,
L. T. Yang,
Z. Zeng,
J. P. Cheng,
J. L. Li
Abstract:
A model of the Li-diffused inactive layer in P-type high purity germanium detectors is built to describe the transportation of charge carriers and calculate the charge collection efficiency therein. The model is applied to calculate charge collection efficiency of a P-type point-contact germanium detector used in rare event physics experiments and validated in another P-type semi-planar germanium…
▽ More
A model of the Li-diffused inactive layer in P-type high purity germanium detectors is built to describe the transportation of charge carriers and calculate the charge collection efficiency therein. The model is applied to calculate charge collection efficiency of a P-type point-contact germanium detector used in rare event physics experiments and validated in another P-type semi-planar germanium detector. The calculated charge collection efficiency curves are well consistent with measurements for both detectors. Effects of the Li doping processes on the charge collection efficiency are discussed based on the model. This model can be easily extended to other P-type germanium detectors, for instance, the P-type broad-energy Ge detector, and the P-type inverted-coaxial point-contact detector.
△ Less
Submitted 28 December, 2022; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Constraints on Sub-GeV Dark Matter--Electron Scattering from the CDEX-10 Experiment
Authors:
Z. Y. Zhang,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
H. B. Li
, et al. (60 additional authors not shown)
Abstract:
We present improved germanium-based constraints on sub-GeV dark matter via dark matter--electron ($χ$-$e$) scattering using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment. Using a novel calculation technique, we attain predicted $χ$-$e$ scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvem…
▽ More
We present improved germanium-based constraints on sub-GeV dark matter via dark matter--electron ($χ$-$e$) scattering using the 205.4 kg$\cdot$day dataset from the CDEX-10 experiment. Using a novel calculation technique, we attain predicted $χ$-$e$ scattering spectra observable in high-purity germanium detectors. In the heavy mediator scenario, our results achieve 3 orders of magnitude of improvement for $m_χ$ larger than 80 MeV/c$^2$ compared to previous germanium-based $χ$-$e$ results. We also present the most stringent $χ$-$e$ cross-section limit to date among experiments using solid-state detectors for $m_χ$ larger than 90 MeV/c$^2$ with heavy mediators and $m_χ$ larger than 100 MeV/c$^2$ with electric dipole coupling. The result proves the feasibility and demonstrates the vast potential of a new $χ$-$e$ detection method with high-purity germanium detectors in ultralow radioactive background.
△ Less
Submitted 21 November, 2022; v1 submitted 8 June, 2022;
originally announced June 2022.
-
Search for Neutrinoless Double-Beta Decay of $^{76}$Ge with a Natural Broad Energy Germanium Detector
Authors:
CDEX collaboration,
W. H. Dai,
H. Ma,
Q. Yue,
Z. She,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang
, et al. (61 additional authors not shown)
Abstract:
A natural broad energy germanium (BEGe) detector is operated in the China Jinping Underground Laboratory (CJPL) for a feasibility study of building the next generation experiment of the neutrinoless double-beta (0{$νββ$}) decay of $^{76}$Ge. The setup of the prototype facility, characteristics of the BEGe detector, background reduction methods, and data analysis are described in this paper. A back…
▽ More
A natural broad energy germanium (BEGe) detector is operated in the China Jinping Underground Laboratory (CJPL) for a feasibility study of building the next generation experiment of the neutrinoless double-beta (0{$νββ$}) decay of $^{76}$Ge. The setup of the prototype facility, characteristics of the BEGe detector, background reduction methods, and data analysis are described in this paper. A background index of 6.4$\times$10$^{-3}$ counts/(keV$\cdot$kg$\cdot$day) is achieved and 1.86 times lower than our previous result of the CDEX-1 detector. No signal is observed with an exposure of 186.4 kg$\cdot$day, thus a limit on the half life of $^{76}$Ge 0$νββ$ decay is set at T$_{1/2}^{0ν}$ $>$ 5.62$\times$10$^{22}$ yr at 90% C.L.. The limit corresponds to an effective Majorana neutrino mass in the range of 4.6 $\sim$ 10.3 eV, dependent on the nuclear matrix elements.
△ Less
Submitted 5 August, 2022; v1 submitted 21 May, 2022;
originally announced May 2022.
-
Constraints on sub-GeV dark matter boosted by cosmic rays from the CDEX-10 experiment at the China Jinping Underground Laboratory
Authors:
R. Xu,
L. T. Yang,
Q. Yue,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
X. Y. Guo,
Q. J. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia,
X. Jiang,
H. B. Li
, et al. (60 additional authors not shown)
Abstract:
We present new constraints on light dark matter boosted by cosmic rays (CRDM) using the 205.4 kg day data of the CDEX-10 experiment conducted at the China Jinping Underground Laboratory. The Monte Carlo simulation package CJPL\_ESS was employed to evaluate the Earth shielding effect. Several key factors have been introduced and discussed in our CRDM analysis, including the contributions from heavi…
▽ More
We present new constraints on light dark matter boosted by cosmic rays (CRDM) using the 205.4 kg day data of the CDEX-10 experiment conducted at the China Jinping Underground Laboratory. The Monte Carlo simulation package CJPL\_ESS was employed to evaluate the Earth shielding effect. Several key factors have been introduced and discussed in our CRDM analysis, including the contributions from heavier CR nuclei than proton and helium, the inhomogeneity of CR distribution, and the impact of the form factor in the Earth attenuation calculation. Our result excludes the dark matter--nucleon elastic scattering cross-section region from $1.7\times 10^{-30}$ to $10^{-26}~\rm cm^2$ for dark matter of 10 keV$/c^2$ to 1 GeV$/c^2$.
△ Less
Submitted 16 September, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
-
Studies of the Earth shielding effect to direct dark matter searches at the China Jinping Underground Laboratory
Authors:
Z. Z. Liu,
L. T. Yang,
Q. Yue,
C. H. Yeh,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
X. Y. Guo,
Q. J. Guo,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
H. T. Jia
, et al. (58 additional authors not shown)
Abstract:
Dark matter direct detection experiments mostly operate at deep underground laboratories. It is necessary to consider shielding effect of the Earth, especially for dark matter particles interacting with a large cross section. We analyzed and simulated the Earth shielding effect for dark matter at the China Jinping Underground Laboratory (CJPL) with a simulation package, CJPL Earth Shielding Simula…
▽ More
Dark matter direct detection experiments mostly operate at deep underground laboratories. It is necessary to consider shielding effect of the Earth, especially for dark matter particles interacting with a large cross section. We analyzed and simulated the Earth shielding effect for dark matter at the China Jinping Underground Laboratory (CJPL) with a simulation package, CJPL Earth Shielding Simulation code (CJPL\_ESS), which is applicable to other underground locations. The further constraints on the $χ$-N cross section exclusion regions are derived based on the studies with CDEX experiment data.
△ Less
Submitted 9 March, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Single-qubit universal classifier implemented on an ion-trap quantum device
Authors:
Tarun Dutta,
Adrián Pérez-Salinas,
Jasper Phua Sing Cheng,
José Ignacio Latorre,
Manas Mukherjee
Abstract:
Quantum computers can provide solutions to classically intractable problems under specific and adequate conditions. However, current devices have only limited computational resources, and an effort is made to develop useful quantum algorithms under these circumstances. This work experimentally demonstrates that a single-qubit device can host a universal classifier. The quantum processor used in th…
▽ More
Quantum computers can provide solutions to classically intractable problems under specific and adequate conditions. However, current devices have only limited computational resources, and an effort is made to develop useful quantum algorithms under these circumstances. This work experimentally demonstrates that a single-qubit device can host a universal classifier. The quantum processor used in this work is based on ion traps, providing highly accurate control on small systems. The algorithm chosen is the re-uploading scheme, which can address general learning tasks. Ion traps suit the needs of accurate control required by re-uploading. In the experiment here presented, a set of non-trivial classification tasks are successfully carried. The training procedure is performed in two steps combining simulation and experiment. Final results are benchmarked against exact simulations of the same method and also classical algorithms, showing a competitive performance of the ion-trap quantum classifier. This work constitutes the first experimental implementation of a classification algorithm based on the re-uploading scheme.
△ Less
Submitted 22 November, 2021; v1 submitted 26 June, 2021;
originally announced June 2021.
-
First experimental constraints on WIMP couplings in the effective field theory framework from CDEX
Authors:
Y. Wang,
Z. Zeng,
Q. Yue,
L. T. Yang,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
C. Y. Chiang,
W. H. Dai,
Z. Deng,
C. H. Fang,
X. P. Geng,
H. Gong,
Q. J. Guo,
X. Y. Guo,
H. J. He,
L. He,
S. M. He,
J. W. Hu,
T. C. Huang
, et al. (63 additional authors not shown)
Abstract:
We present weakly interacting massive particles (WIMPs) search results performed using two approaches of effective field theory from the China Dark Matter Experiment (CDEX), based on the data from both CDEX-1B and CDEX-10 stages. In the nonrelativistic effective field theory approach, both time-integrated and annual modulation analyses were used to set new limits for the coupling of WIMP-nucleon e…
▽ More
We present weakly interacting massive particles (WIMPs) search results performed using two approaches of effective field theory from the China Dark Matter Experiment (CDEX), based on the data from both CDEX-1B and CDEX-10 stages. In the nonrelativistic effective field theory approach, both time-integrated and annual modulation analyses were used to set new limits for the coupling of WIMP-nucleon effective operators at 90% confidence level (C.L.) and improve over the current bounds in the low $m_χ$ region. In the chiral effective field theory approach, data from CDEX-10 were used to set an upper limit on WIMP-pion coupling at 90% C.L. We for the first time extended the limit to the $m_χ<$ 6 GeV/$c^2$ region.
△ Less
Submitted 26 April, 2021; v1 submitted 30 July, 2020;
originally announced July 2020.
-
In-situ gamma-ray background measurements for next generation CDEX experiment in the China Jinping Underground Laboratory
Authors:
H. Ma,
Z. She,
W. H. Zeng,
Z. Zeng,
M. K. Jing,
Q. Yue,
J. P. Cheng,
J. L. Li,
H. Zhang
Abstract:
In-situ $γ$-ray measurements were performed using a portable high purity germanium spectrometer in Hall-C at the second phase of the China Jinping Underground Laboratory (CJPL-II) to characterise the environmental radioactivity background below 3 MeV and provide ambient $γ$-ray background parameters for next generation of China Dark Matter Experiment (CDEX). The integral count rate of the spectrum…
▽ More
In-situ $γ$-ray measurements were performed using a portable high purity germanium spectrometer in Hall-C at the second phase of the China Jinping Underground Laboratory (CJPL-II) to characterise the environmental radioactivity background below 3 MeV and provide ambient $γ$-ray background parameters for next generation of China Dark Matter Experiment (CDEX). The integral count rate of the spectrum was 46.8 cps in the energy range of 60 to 2700 keV. Detection efficiencies of the spectrometer corresponding to concrete walls and surrounding air were obtained from numerical calculation and Monte Carlo simulation, respectively. The radioactivity concentrations of the walls in the Hall-C were calculated to be ${6.8\pm1.5}$ Bq/kg for ${^{238}}$U, ${5.4\pm0.6}$ Bq/kg for ${^{232}}$Th, ${81.9\pm14.4}$ Bq/kg for ${^{40}}$K. Based on the measurement results, the expected background rates from these primordial radionuclides of future CDEX experiment were simulated in unit of counts per keV per ton per year (cpkty) for the energy ranges of 2 to 4 keV and around 2 MeV. The total background level from primordial radionuclides with decay products in secular equilibrium are ${7.0 \times 10^{-2}}$ and ${3.1 \times 10^{-3}}$ cpkty for energy ranges of 2 keV to 4 keV and around 2 MeV, respectively.
△ Less
Submitted 24 January, 2021; v1 submitted 11 May, 2020;
originally announced May 2020.
-
Improved limits on solar axions and bosonic dark matter from the CDEX-1B experiment using the profile likelihood ratio method
Authors:
Y. Wang,
Q. Yue,
S. K. Liu,
K. J. Kang,
Y. J. Li,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
X. P. Geng,
H. Gong,
P. Gu,
X. Y. Guo,
H. T. He,
L. He,
S. M. He,
J. W. Hu,
H. X. Huang,
T. C. Huang,
L. P. Jia,
H. B. Li,
H. Li
, et al. (55 additional authors not shown)
Abstract:
We present the improved constraints on couplings of solar axions and more generic bosonic dark matter particles using 737.1 kg-days of data from the CDEX-1B experiment. The CDEX-1B experiment, located at the China Jinping Underground Laboratory, primarily aims at the direct detection of weakly interacting massive particles using a p-type point-contact germanium detector. We adopt the profile likel…
▽ More
We present the improved constraints on couplings of solar axions and more generic bosonic dark matter particles using 737.1 kg-days of data from the CDEX-1B experiment. The CDEX-1B experiment, located at the China Jinping Underground Laboratory, primarily aims at the direct detection of weakly interacting massive particles using a p-type point-contact germanium detector. We adopt the profile likelihood ratio method for analysis of data in the presence of backgrounds. An energy threshold of 160 eV was achieved, much better than the 475 eV of CDEX-1A with an exposure of 335.6 kg-days. This significantly improves the sensitivity for the bosonic dark matter below 0.8 keV among germanium detectors. Limits are also placed on the coupling $g_{Ae} < 2.48 \times 10^{-11}$ from Compton, bremsstrahlung, atomic-recombination and de-excitation channels and $g^{eff}_{AN} \times g_{Ae} < 4.14 \times 10^{-17}$ from a $^{57}$Fe M1 transition at 90\% confidence level.
△ Less
Submitted 26 April, 2021; v1 submitted 8 November, 2019;
originally announced November 2019.
-
Direct Detection Constraints on Dark Photons with CDEX-10 Experiment at the China Jinping Underground Laboratory
Authors:
Z. She,
L. P. Jia,
Q. Yue,
H. Ma,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
X. P. Geng,
H. Gong,
P. Gu,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
H. T. He,
J. W. Hu,
T. C. Huang,
H. X. Huang
, et al. (59 additional authors not shown)
Abstract:
We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/…
▽ More
We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/${c^2}$ in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90\% confidence level with ${m_V}$ from 0.1 to 4.0 keV/${c^2}$ are set from 449.6 kg-day data, with a minimum of ${\rm{κ=1.3 \times 10^{-15}}}$ at ${\rm{m_V=200\ eV/c^2}}$.
△ Less
Submitted 18 March, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Constraints on Spin-Independent Nucleus Scattering with sub-GeV Weakly Interacting Massive Particle Dark Matter from the CDEX-1B Experiment at the China Jin-Ping Laboratory
Authors:
Z. Z. Liu,
Q. Yue,
L. T. Yang,
K. J. Kang,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
Q. Du,
H. Gong,
X. Y. Guo,
L. He,
S. M. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. B. Li,
H. Li
, et al. (46 additional authors not shown)
Abstract:
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses ($m_χ$) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg$\cdot$day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg$\cdot$day exposure and 250…
▽ More
We report results on the searches of weakly interacting massive particles (WIMPs) with sub-GeV masses ($m_χ$) via WIMP-nucleus spin-independent scattering with Migdal effect incorporated. Analysis on time-integrated (TI) and annual modulation (AM) effects on CDEX-1B data are performed, with 737.1 kg$\cdot$day exposure and 160 eVee threshold for TI analysis, and 1107.5 kg$\cdot$day exposure and 250 eVee threshold for AM analysis. The sensitive windows in $m_χ$ are expanded by an order of magnitude to lower DM masses with Migdal effect incorporated. New limits on $σ_{χN}^{\rm SI}$ at 90\% confidence level are derived as $2\times$10$^{-32}\sim7\times$10$^{-35}$ $\rm cm^2$ for TI analysis at $m_χ\sim$ 50$-$180 MeV/$c^2$, and $3\times$10$^{-32}\sim9\times$10$^{-38}$ $\rm cm^2$ for AM analysis at $m_χ\sim$75 MeV/$c^2-$3.0 GeV/$c^2$.
△ Less
Submitted 15 October, 2019; v1 submitted 1 May, 2019;
originally announced May 2019.
-
Search for Light Weakly-Interacting-Massive-Particle Dark Matter by Annual Modulation Analysis with a Point-Contact Germanium Detector at the China Jinping Underground Laboratory
Authors:
L. T. Yang,
H. B. Li,
Q. Yue,
H. Ma,
K. J. Kang,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
Z. Deng,
Q. Du,
H. Gong,
Q. J. Guo,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. Li,
J. M. Li
, et al. (50 additional authors not shown)
Abstract:
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass $p$-type point-contact germanium detector of the CDEX-1B experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2 yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus ($χ$-$N$)…
▽ More
We present results on light weakly interacting massive particle (WIMP) searches with annual modulation (AM) analysis on data from a 1-kg mass $p$-type point-contact germanium detector of the CDEX-1B experiment at the China Jinping Underground Laboratory. Datasets with a total live time of 3.2 yr within a 4.2 yr span are analyzed with analysis threshold of 250 eVee. Limits on WIMP-nucleus ($χ$-$N$) spin-independent cross sections as function of WIMP mass ($m_χ$) at 90\% confidence level (C.L.) are derived using the dark matter halo model. Within the context of the standard halo model, the 90\% C.L. allowed regions implied by the DAMA/LIBRA and CoGeNT AM-based analysis are excluded at $>$99.99\% and 98\% C.L., respectively. These results correspond to the best sensitivity at $m_χ$$<$6$~{\rm GeV}/c^2$ among WIMP AM measurements to date.
△ Less
Submitted 25 November, 2019; v1 submitted 29 April, 2019;
originally announced April 2019.
-
Performances of a prototype point-contact germanium detector immersed in liquid nitrogen for light dark matter search
Authors:
H. Jiang,
L. T. Yang,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. B. Li,
H. Li,
J. M. Li,
J. Li,
X. Li
, et al. (48 additional authors not shown)
Abstract:
The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China JinPing underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher…
▽ More
The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China JinPing underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher rise-time resolution of the CDEX-10 prototype detector as compared with CDEX-1B, we identified the origin of an observed category of extremely fast events. For data analysis of the CDEX-10 prototype, we introduced and applied an improved bulk/surface event discrimination method. The results of the new method were compared to those of the CDEX-1B spectrum. Both sets of results showed good consistency in the 0--12 keVee energy range, except for the 8.0 keV K-shell X-ray peak from the external copper.
△ Less
Submitted 20 October, 2018;
originally announced October 2018.
-
Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg ${\times}$ day Data of the CDEX-10 Experiment
Authors:
H. Jiang,
L. P. Jia,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
H. B. Li,
H. Li,
J. M. Li,
J. Li,
X. Li,
X. Q. Li
, et al. (48 additional authors not shown)
Abstract:
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China Jinping Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidenc…
▽ More
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China Jinping Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass ($m_χ$) of 5 GeV/${c}^2$ are achieved. The lower reach of $m_χ$ is extended to 2 GeV/${c}^2$.
△ Less
Submitted 26 June, 2018; v1 submitted 25 February, 2018;
originally announced February 2018.
-
Limits on light WIMPs with a 1 kg-scale germanium detector at 160 eVee physics threshold at the China Jinping Underground Laboratory
Authors:
L. T. Yang,
H. B. Li,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Aǧartioǧlu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. Li,
J. M. Li,
J. Li,
X. Li
, et al. (43 additional authors not shown)
Abstract:
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMP…
▽ More
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMPs to 2 GeV and improve over our earlier bounds at WIMP mass less than 6 GeV.
△ Less
Submitted 26 June, 2018; v1 submitted 18 October, 2017;
originally announced October 2017.
-
Constraints on Axion couplings from the CDEX-1 experiment at the China Jinping Underground Laboratory
Authors:
S. K. Liu,
Q. Yue,
K. J. Kang,
J. P. Cheng,
H. T. Wong,
Y. J. Li,
H. B. Li,
S. T. Lin,
J. P. Chang,
J. H. Chen,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
H. J. He,
Q. J. He,
H. X. Huang,
H. Jiang,
J. M. Li,
J. Li,
J. Li,
X. Li,
X. Q. Li
, et al. (49 additional authors not shown)
Abstract:
We report the results of searches for solar axions and galactic dark matter axions or axion-like particles with CDEX-1 experiment at the China Jinping Underground Laboratory, using 335.6 kg-days of data from a p-type point-contact germanium detector. The data are compatible with the background model and no excess signals are observed. Limits of solar axions on the model independent coupling…
▽ More
We report the results of searches for solar axions and galactic dark matter axions or axion-like particles with CDEX-1 experiment at the China Jinping Underground Laboratory, using 335.6 kg-days of data from a p-type point-contact germanium detector. The data are compatible with the background model and no excess signals are observed. Limits of solar axions on the model independent coupling $g_{Ae}<2.5\times10^{-11}$ from Compton, bremsstrahlung, atomic-recombination and deexcitation channel and $g^{\text{eff}}_{AN}\times g_{Ae}<6.1\times10^{-17}$ from $^{57}$Fe M1 transition at 90 % confidence level are derived. Within the framework of the DFSZ and KSVZ models, our results exclude the axion mass heavier than 0.9 eV/c$^{2}$ and 173 eV/c$^{2}$, respectively. The derived constraints for dark matter axions below 1 keV improves over the previous results.
△ Less
Submitted 24 October, 2016;
originally announced October 2016.
-
A Search of Low-Mass WIMPs with p-type Point Contact Germanium Detector in the CDEX-1 Experiment
Authors:
W. Zhao,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
S. T. Lin,
J. P. Chang,
J. H. Chen,
Q. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. Li,
J. Li,
J. M. Li,
X. Li
, et al. (48 additional authors not shown)
Abstract:
The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this ex…
▽ More
The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this experiment. No excess of unidentified events are observed after subtraction of known background. Using 335.6 kg-days of data, exclusion constraints on the WIMP-nucleon spin-independent and spin-dependent couplings are derived.
△ Less
Submitted 18 January, 2016;
originally announced January 2016.
-
Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory
Authors:
Q. Yue,
W. Zhao,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
J. P. Chang,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. M. Li,
J. Li,
J. Li,
X. Li
, et al. (49 additional authors not shown)
Abstract:
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part o…
▽ More
We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.
△ Less
Submitted 10 November, 2014; v1 submitted 19 April, 2014;
originally announced April 2014.
-
Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory
Authors:
S. K. Liu,
Q. Yue,
K. J. Kang,
J. P. Cheng,
H. T. Wong,
Y. J. Li,
S. T. Lin,
J. P. Chang,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. M. Li,
J. Li,
J. Li
, et al. (51 additional authors not shown)
Abstract:
The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is deriv…
▽ More
The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.
△ Less
Submitted 1 August, 2014; v1 submitted 21 March, 2014;
originally announced March 2014.
-
Calibration and performance of the STAR Muon Telescope Detector using cosmic rays
Authors:
C. Yang,
X. J. Huang,
C. M. Du,
B. C. Huang,
Z. Ahammed,
A. Banerjee,
P. Bhattarari,
S. Biswas,
B. Bowen,
J. Butterworth,
M. Calderón de la Barca Sánchez,
H. Carson,
S. Chattopadhyay,
D. Cebra,
H. F. Chen,
J. P. Cheng,
M. Codrington,
G. Eppley,
C. Flores,
F. Geurts,
G. W. Hoffmann,
A. Jentsch,
A. Kesich,
C. Li,
Y. J. Li
, et al. (13 additional authors not shown)
Abstract:
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained…
▽ More
We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained were ~100 ps and ~1-2 cm, respectively. These values are comparable to those obtained from cosmic-ray bench tests and test beams.
△ Less
Submitted 5 February, 2014;
originally announced February 2014.
-
First results on low-mass WIMP from the CDEX-1 experiment at the China Jinping underground Laboratory
Authors:
W. Zhao,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
Y. Bai,
Y. Bi,
J. P. Chang,
N. Chen,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
C. Du,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
X. H. Hu,
H. X. Huang,
T. R. Huang,
H. Jiang
, et al. (54 additional authors not shown)
Abstract:
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{…
▽ More
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.
△ Less
Submitted 8 August, 2013; v1 submitted 18 June, 2013;
originally announced June 2013.