-
CMRxRecon2024: A Multi-Modality, Multi-View K-Space Dataset Boosting Universal Machine Learning for Accelerated Cardiac MRI
Authors:
Zi Wang,
Fanwen Wang,
Chen Qin,
Jun Lyu,
Ouyang Cheng,
Shuo Wang,
Yan Li,
Mengyao Yu,
Haoyu Zhang,
Kunyuan Guo,
Zhang Shi,
Qirong Li,
Ziqiang Xu,
Yajing Zhang,
Hao Li,
Sha Hua,
Binghua Chen,
Longyu Sun,
Mengting Sun,
Qin Li,
Ying-Hua Chu,
Wenjia Bai,
Jing Qin,
Xiahai Zhuang,
Claudia Prieto
, et al. (7 additional authors not shown)
Abstract:
Cardiac magnetic resonance imaging (MRI) has emerged as a clinically gold-standard technique for diagnosing cardiac diseases, thanks to its ability to provide diverse information with multiple modalities and anatomical views. Accelerated cardiac MRI is highly expected to achieve time-efficient and patient-friendly imaging, and then advanced image reconstruction approaches are required to recover h…
▽ More
Cardiac magnetic resonance imaging (MRI) has emerged as a clinically gold-standard technique for diagnosing cardiac diseases, thanks to its ability to provide diverse information with multiple modalities and anatomical views. Accelerated cardiac MRI is highly expected to achieve time-efficient and patient-friendly imaging, and then advanced image reconstruction approaches are required to recover high-quality, clinically interpretable images from undersampled measurements. However, the lack of publicly available cardiac MRI k-space dataset in terms of both quantity and diversity has severely hindered substantial technological progress, particularly for data-driven artificial intelligence. Here, we provide a standardized, diverse, and high-quality CMRxRecon2024 dataset to facilitate the technical development, fair evaluation, and clinical transfer of cardiac MRI reconstruction approaches, towards promoting the universal frameworks that enable fast and robust reconstructions across different cardiac MRI protocols in clinical practice. To the best of our knowledge, the CMRxRecon2024 dataset is the largest and most diverse publicly available cardiac k-space dataset. It is acquired from 330 healthy volunteers, covering commonly used modalities, anatomical views, and acquisition trajectories in clinical cardiac MRI workflows. Besides, an open platform with tutorials, benchmarks, and data processing tools is provided to facilitate data usage, advanced method development, and fair performance evaluation.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
-
Active tuning of plasmon damping via light induced magnetism
Authors:
Oscar Hsu-Cheng Cheng,
Boqin Zhao,
Zachary Brawley,
Dong Hee Son,
Matthew Sheldon
Abstract:
Circularly polarized optical excitation of plasmonic nanostructures causes coherent circulating motion of their electrons, which in turn, gives rise to strong optically induced magnetization - a phenomenon known as the inverse Faraday effect (IFE). In this study we report how the IFE also significantly decreases plasmon damping. By modulating the optical polarization state incident on achiral plas…
▽ More
Circularly polarized optical excitation of plasmonic nanostructures causes coherent circulating motion of their electrons, which in turn, gives rise to strong optically induced magnetization - a phenomenon known as the inverse Faraday effect (IFE). In this study we report how the IFE also significantly decreases plasmon damping. By modulating the optical polarization state incident on achiral plasmonic nanostructures from linear to circular, we observe reversible increases of reflectance by 78% as well as simultaneous increases of optical field concentration by 35.7% under 10^9 W/m^2 continuous wave (CW) optical excitation. These signatures of decreased plasmon damping were also monitored in the presence of an externally applied magnetic field (0.2 T). The combined interactions allow an estimate of the light-induced magnetization, which corresponds to an effective magnetic field of ~1.3 T during circularly polarized CW excitation (10^9 W/m^2). We rationalize the observed decreases in plasmon damping in terms of the Lorentz forces acting on the circulating electron trajectories. Our results outline strategies for actively modulating intrinsic losses in the metal, and thereby, the optical mode quality and field concentration via opto-magnetic effects encoded in the polarization state of incident light.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
Building Usable Witness Encryption
Authors:
Gavin Uberti,
Kevin Luo,
Oliver Cheng,
Wittmann Goh
Abstract:
Witness encryption using multilinear maps was first proposed in 2013, and has continued to evolve since. In this paper, we build on an open-source multilinear map implementation by Carmer and Malozemoff of the graded encoding scheme CLT13 with asymmetric modifications. Using this map, we created the world's first ciphertext encoded with a candidate witness encryption scheme. Finally, using a reduc…
▽ More
Witness encryption using multilinear maps was first proposed in 2013, and has continued to evolve since. In this paper, we build on an open-source multilinear map implementation by Carmer and Malozemoff of the graded encoding scheme CLT13 with asymmetric modifications. Using this map, we created the world's first ciphertext encoded with a candidate witness encryption scheme. Finally, using a reduction from Sudoku to Exact Cover, we encrypted the private key to a Bitcoin wallet with 22,700 Satoshi using a Sudoku.
△ Less
Submitted 8 December, 2021;
originally announced December 2021.
-
The Connection Between Plasmon Decay Dynamics and the SERS background: Inelastic Scattering from Non-Thermal and Hot Carriers
Authors:
Shengxiang Wu,
Oscar Hsu-Cheng Cheng,
Boqin Zhao,
Nicki Hogan,
Annika Lee,
Dong Hee Son,
Matthew Sheldon
Abstract:
Recent studies have established that the anti-Stokes Raman signal from plasmonic metal nanostructures can be used to determine the two separate temperatures that characterize carriers inside the metal -- the temperature of photoexcited "hot carriers" and carriers that are thermalized with the metal lattice. However, the related signal in the Stokes spectral region has historically impeded surface…
▽ More
Recent studies have established that the anti-Stokes Raman signal from plasmonic metal nanostructures can be used to determine the two separate temperatures that characterize carriers inside the metal -- the temperature of photoexcited "hot carriers" and carriers that are thermalized with the metal lattice. However, the related signal in the Stokes spectral region has historically impeded surface enhanced Raman spectroscopy (SERS), as the vibrational peaks of adsorbed molecules are always accompanied by the broad background of the metal substrate. The fundamental source of the metal signal, and hence its contribution to the spectrum, has been unclear. Here, we outline a unified theoretical model that describes both the temperature-dependent behavior and the broad spectral distribution. We suggest that the majority of the Raman signal is from inelastic scattering directly with non-thermal carriers that have been excited via damping of the surface plasmon. In addition, a significant spectral component (~ 1%) is due to a sub-population of hot carriers in an elevated thermal distribution. We have performed temperature and power-dependent Raman experiments to show how a simple fitting procedure reveals the plasmon dephasing time, as well as the temperatures of the hot carriers and the metal lattice, in order to correlate these parameters with quantitative Raman analysis of chemical species adsorbed on metal surface.
△ Less
Submitted 24 March, 2021; v1 submitted 14 October, 2020;
originally announced October 2020.
-
1,000-Fold Enhancement of Light-Induced Magnetism in Plasmonic Au Nanoparticles
Authors:
Oscar Hsu-Cheng Cheng,
Dong Hee Son,
Matthew Sheldon
Abstract:
Strategies for ultrafast optical control of magnetism have been a topic of intense research for several decades because of the potential impact in technologies such as magnetic memory, spintronics, and quantum computation, as well as the opportunities for non-linear optical control and modulation in applications such as optical isolation and non-reciprocity. Here we report the first experimental q…
▽ More
Strategies for ultrafast optical control of magnetism have been a topic of intense research for several decades because of the potential impact in technologies such as magnetic memory, spintronics, and quantum computation, as well as the opportunities for non-linear optical control and modulation in applications such as optical isolation and non-reciprocity. Here we report the first experimental quantification of optically induced magnetization in plasmonic Au nanoparticles due to the inverse Faraday effect (IFE). The induced magnetic moment in nanoparticles is found to be ~1,000x larger than that observed in bulk Au, and ~20x larger than the magnetic moment from optimized magnetic nanoparticle colloids such as magnetite. Furthermore, the magnetization and demagnetization kinetics are instantaneous within the sub-picosecond time resolution of our study, supporting a mechanism of coherent transfer of angular momentum from the circularly polarized excitation to the orbital angular momentum of the electron gas.
△ Less
Submitted 25 April, 2019;
originally announced April 2019.
-
Computer-Aided Knee Joint Magnetic Resonance Image Segmentation - A Survey
Authors:
Boyu Zhang,
Yingtao Zhang,
H. D. Cheng,
Min Xian,
Shan Gai,
Olivia Cheng,
Kuan Huang
Abstract:
Osteoarthritis (OA) is one of the major health issues among the elderly population. MRI is the most popular technology to observe and evaluate the progress of OA course. However, the extreme labor cost of MRI analysis makes the process inefficient and expensive. Also, due to human error and subjective nature, the inter- and intra-observer variability is rather high. Computer-aided knee MRI segment…
▽ More
Osteoarthritis (OA) is one of the major health issues among the elderly population. MRI is the most popular technology to observe and evaluate the progress of OA course. However, the extreme labor cost of MRI analysis makes the process inefficient and expensive. Also, due to human error and subjective nature, the inter- and intra-observer variability is rather high. Computer-aided knee MRI segmentation is currently an active research field because it can alleviate doctors and radiologists from the time consuming and tedious job, and improve the diagnosis performance which has immense potential for both clinic and scientific research. In the past decades, researchers have investigated automatic/semi-automatic knee MRI segmentation methods extensively. However, to the best of our knowledge, there is no comprehensive survey paper in this field yet. In this survey paper, we classify the existing methods by their principles and discuss the current research status and point out the future research trend in-depth.
△ Less
Submitted 13 February, 2018;
originally announced February 2018.