-
Enabling Additive Manufacturing Part Inspection of Digital Twins via Collaborative Virtual Reality
Authors:
Vuthea Chheang,
Saurabh Narain,
Garrett Hooten,
Robert Cerda,
Brian Au,
Brian Weston,
Brian Giera,
Peer-Timo Bremer,
Haichao Miao
Abstract:
Digital twins (DTs) are an emerging capability in additive manufacturing (AM), set to revolutionize design optimization, inspection, in situ monitoring, and root cause analysis. AM DTs typically incorporate multimodal data streams, ranging from machine toolpaths and in-process imaging to X-ray CT scans and performance metrics. Despite the evolution of DT platforms, challenges remain in effectively…
▽ More
Digital twins (DTs) are an emerging capability in additive manufacturing (AM), set to revolutionize design optimization, inspection, in situ monitoring, and root cause analysis. AM DTs typically incorporate multimodal data streams, ranging from machine toolpaths and in-process imaging to X-ray CT scans and performance metrics. Despite the evolution of DT platforms, challenges remain in effectively inspecting them for actionable insights, either individually or in a multidisciplinary team setting. Quality assurance, manufacturing departments, pilot labs, and plant operations must collaborate closely to reliably produce parts at scale. This is particularly crucial in AM where complex structures require a collaborative and multidisciplinary approach. Additionally, the large-scale data originating from different modalities and their inherent 3D nature pose significant hurdles for traditional 2D desktop-based inspection methods. To address these challenges and increase the value proposition of DTs, we introduce a novel virtual reality (VR) framework to facilitate collaborative and real-time inspection of DTs in AM. This framework includes advanced features for intuitive alignment and visualization of multimodal data, visual occlusion management, streaming large-scale volumetric data, and collaborative tools, substantially improving the inspection of AM components and processes to fully exploit the potential of DTs in AM.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
A Virtual Environment for Collaborative Inspection in Additive Manufacturing
Authors:
Vuthea Chheang,
Brian Thomas Weston,
Robert William Cerda,
Brian Au,
Brian Giera,
Peer-Timo Bremer,
Haichao Miao
Abstract:
Additive manufacturing (AM) techniques have been used to enhance the design and fabrication of complex components for various applications in the medical, aerospace, energy, and consumer products industries. A defining feature for many AM parts is the complex internal geometry enabled by the printing process. However, inspecting these internal structures requires volumetric imaging, i.e., X-ray CT…
▽ More
Additive manufacturing (AM) techniques have been used to enhance the design and fabrication of complex components for various applications in the medical, aerospace, energy, and consumer products industries. A defining feature for many AM parts is the complex internal geometry enabled by the printing process. However, inspecting these internal structures requires volumetric imaging, i.e., X-ray CT, leading to the well-known challenge of visualizing complex 3D geometries using 2D desktop interfaces. Furthermore, existing tools are limited to single-user systems making it difficult to jointly discuss or share findings with a larger team, i.e., the designers, manufacturing experts, and evaluation team. In this work, we present a collaborative virtual reality (VR) for the exploration and inspection of AM parts. Geographically separated experts can virtually inspect and jointly discuss data. It also supports VR and non-VR users, who can be spectators in the VR environment. Various features for data exploration and inspection are developed and enhanced via real-time synchronization. We followed usability and interface verification guidelines using Nielsen's heuristics approach. Furthermore, we conducted exploratory and semi-structured interviews with domain experts to collect qualitative feedback. Results reveal potential benefits, applicability, and current limitations. The proposed collaborative VR environment provides a new basis and opens new research directions for virtual inspection and team collaboration in AM settings.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
-
Automated Characterization of Stenosis in Invasive Coronary Angiography Images with Convolutional Neural Networks
Authors:
Benjamin Au,
Uri Shaham,
Sanket Dhruva,
Georgios Bouras,
Ecaterina Cristea,
Alexandra Lansky MD,
Andreas Coppi,
Fred Warner,
Shu-Xia Li,
Harlan Krumholz
Abstract:
The determination of a coronary stenosis and its severity in current clinical workflow is typically accomplished manually via physician visual assessment (PVA) during invasive coronary angiography. While PVA has shown large inter-rater variability, the more reliable and accurate alternative of Quantitative Coronary Angiography (QCA) is challenging to perform in real-time due to the busy workflow i…
▽ More
The determination of a coronary stenosis and its severity in current clinical workflow is typically accomplished manually via physician visual assessment (PVA) during invasive coronary angiography. While PVA has shown large inter-rater variability, the more reliable and accurate alternative of Quantitative Coronary Angiography (QCA) is challenging to perform in real-time due to the busy workflow in cardiac catheterization laboratories. We propose a deep learning approach based on Convolutional Neural Networks (CNN) that automatically characterizes and analyzes coronary stenoses in real-time by automating clinical tasks performed during QCA. Our deep learning methods for localization, segmentation and classification of stenosis in still-frame invasive coronary angiography (ICA) images of the right coronary artery (RCA) achieve performance of 72.7% localization accuracy, 0.704 dice coefficient and 0.825 C-statistic in each respective task. Integrated in an end-to-end approach, our model's performance shows statistically significant improvement in false discovery rate over the current standard in real-time clinical stenosis assessment, PVA. To the best of the authors' knowledge, this is the first time an automated machine learning system has been developed that can implement tasks performed in QCA, and the first time an automated machine learning system has demonstrated significant improvement over the current clinical standard for rapid RCA stenosis analysis.
△ Less
Submitted 19 July, 2018;
originally announced July 2018.