Skip to main content

Showing 1–13 of 13 results for author: Basarab, A

  1. arXiv:2307.16314  [pdf, other

    eess.IV cs.CV cs.LG

    Mask-guided Data Augmentation for Multiparametric MRI Generation with a Rare Hepatocellular Carcinoma

    Authors: Karen Sanchez, Carlos Hinojosa, Kevin Arias, Henry Arguello, Denis Kouame, Olivier Meyrignac, Adrian Basarab

    Abstract: Data augmentation is classically used to improve the overall performance of deep learning models. It is, however, challenging in the case of medical applications, and in particular for multiparametric datasets. For example, traditional geometric transformations used in several applications to generate synthetic images can modify in a non-realistic manner the patients' anatomy. Therefore, dedicated… ▽ More

    Submitted 30 July, 2023; originally announced July 2023.

    Comments: Accepted at IEEE ISBI 2023

  2. arXiv:2306.07440  [pdf, other

    eess.IV cs.CV

    Deep Ultrasound Denoising Using Diffusion Probabilistic Models

    Authors: Hojat Asgariandehkordi, Sobhan Goudarzi, Adrian Basarab, Hassan Rivaz

    Abstract: Ultrasound images are widespread in medical diagnosis for musculoskeletal, cardiac, and obstetrical imaging due to the efficiency and non-invasiveness of the acquisition methodology. However, the acquired images are degraded by acoustic (e.g. reverberation and clutter) and electronic sources of noise. To improve the Peak Signal to Noise Ratio (PSNR) of the images, previous denoising methods often… ▽ More

    Submitted 12 June, 2023; originally announced June 2023.

    Comments: This paper is accepted in IEEE IUS 2023

  3. A Novel Image Denoising Algorithm Using Concepts of Quantum Many-Body Theory

    Authors: Sayantan Dutta, Adrian Basarab, Bertrand Georgeot, Denis Kouamé

    Abstract: Sparse representation of real-life images is a very effective approach in imaging applications, such as denoising. In recent years, with the growth of computing power, data-driven strategies exploiting the redundancy within patches extracted from one or several images to increase sparsity have become more prominent. This paper presents a novel image denoising algorithm exploiting such an image-dep… ▽ More

    Submitted 24 August, 2022; v1 submitted 16 December, 2021; originally announced December 2021.

    Comments: 24 pages, 14 figures; complements and expands arXiv:2108.13778

    Journal ref: Signal Processing, Volume 201, 2022, 108690

  4. arXiv:2010.15491  [pdf, other

    eess.IV cs.CV

    A Novel Fast 3D Single Image Super-Resolution Algorithm

    Authors: Nwigbo Kenule Tuador, Duong Hung Pham, Jérôme Michetti, Adrian Basarab, Denis Kouamé

    Abstract: This paper introduces a novel computationally efficient method of solving the 3D single image super-resolution (SR) problem, i.e., reconstruction of a high-resolution volume from its low-resolution counterpart. The main contribution lies in the original way of handling simultaneously the associated decimation and blurring operators, based on their underlying properties in the frequency domain. In… ▽ More

    Submitted 29 October, 2020; originally announced October 2020.

    Comments: 5 pages, 2 figures

  5. arXiv:2007.05428  [pdf, other

    eess.IV cs.CV

    Joint Blind Deconvolution and Robust Principal Component Analysis for Blood Flow Estimation in Medical Ultrasound Imaging

    Authors: Duong-Hung Pham, Adrian Basarab, Ilyess Zemmoura, Jean-Pierre Remenieras, Denis Kouame

    Abstract: This paper addresses the problem of high-resolution Doppler blood flow estimation from an ultrafast sequence of ultrasound images. Formulating the separation of clutter and blood components as an inverse problem has been shown in the literature to be a good alternative to spatio-temporal singular value decomposition (SVD)-based clutter filtering. In particular, a deconvolution step has recently be… ▽ More

    Submitted 10 July, 2020; originally announced July 2020.

    Comments: 9 pages, 7 figures

  6. arXiv:2005.03080  [pdf, other

    eess.IV cs.CV eess.SP

    Detection of Line Artefacts in Lung Ultrasound Images of COVID-19 Patients via Non-Convex Regularization

    Authors: Oktay Karakuş, Nantheera Anantrasirichai, Amazigh Aguersif, Stein Silva, Adrian Basarab, Alin Achim

    Abstract: In this paper, we present a novel method for line artefacts quantification in lung ultrasound (LUS) images of COVID-19 patients. We formulate this as a non-convex regularisation problem involving a sparsity-enforcing, Cauchy-based penalty function, and the inverse Radon transform. We employ a simple local maxima detection technique in the Radon transform domain, associated with known clinical defi… ▽ More

    Submitted 9 September, 2020; v1 submitted 6 May, 2020; originally announced May 2020.

    Comments: 16 pages, 9 figures

  7. A Tensor Factorization Method for 3D Super-Resolution with Application to Dental CT

    Authors: Janka Hatvani, Adrian Basarab, Jean-Yves Tourneret, Miklós Gyöngy, Denis Kouamé

    Abstract: Available super-resolution techniques for 3D images are either computationally inefficient prior-knowledge-based iterative techniques or deep learning methods which require a large database of known low- and high-resolution image pairs. A recently introduced tensor-factorization-based approach offers a fast solution without the use of known image pairs or strict prior assumptions. In this article… ▽ More

    Submitted 26 July, 2018; originally announced July 2018.

    Comments: This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

  8. arXiv:1707.07089  [pdf, other

    cs.CV

    Motion Compensated Dynamic MRI Reconstruction with Local Affine Optical Flow Estimation

    Authors: Ningning Zhao, Daniel O'Connor, Adrian Basarab, Dan Ruan, Peng Hu, Ke Sheng

    Abstract: This paper proposes a novel framework to reconstruct the dynamic magnetic resonance images (DMRI) with motion compensation (MC). Due to the inherent motion effects during DMRI acquisition, reconstruction of DMRI using motion estimation/compensation (ME/MC) has been studied under a compressed sensing (CS) scheme. In this paper, by embedding the intensity-based optical flow (OF) constraint into the… ▽ More

    Submitted 13 February, 2019; v1 submitted 21 July, 2017; originally announced July 2017.

  9. arXiv:1512.05586  [pdf, other

    cs.CV

    Reconstruction of Enhanced Ultrasound Images From Compressed Measurements Using Simultaneous Direction Method of Multipliers

    Authors: Zhouye Chen, Adrian Basarab, Denis Kouamé

    Abstract: High resolution ultrasound image reconstruction from a reduced number of measurements is of great interest in ultrasound imaging, since it could enhance both the frame rate and image resolution. Compressive deconvolution, combining compressed sensing and image deconvolution, represents an interesting possibility to consider this challenging task. The model of compressive deconvolution includes, in… ▽ More

    Submitted 17 December, 2015; originally announced December 2015.

  10. arXiv:1510.00143  [pdf, other

    cs.CV

    Fast Single Image Super-Resolution

    Authors: Ningning Zhao, Qi Wei, Adrian Basarab, Nicolas Dobigeon, Denis Kouame, Jean-Yves Tourneret

    Abstract: This paper addresses the problem of single image super-resolution (SR), which consists of recovering a high resolution image from its blurred, decimated and noisy version. The existing algorithms for single image SR use different strategies to handle the decimation and blurring operators. In addition to the traditional first-order gradient methods, recent techniques investigate splitting-based met… ▽ More

    Submitted 2 May, 2016; v1 submitted 1 October, 2015; originally announced October 2015.

  11. arXiv:1507.08184  [pdf, other

    cs.CV

    Beamforming through regularized inverse problems in ultrasound medical imaging

    Authors: Teodora Szasz, Adrian Basarab, Denis Kouamé

    Abstract: Beamforming in ultrasound imaging has significant impact on the quality of the final image, controlling its resolution and contrast. Despite its low spatial resolution and contrast, delay-and-sum is still extensively used nowadays in clinical applications, due to its real-time capabilities. The most common alternatives are minimum variance method and its variants, which overcome the drawbacks of d… ▽ More

    Submitted 18 May, 2016; v1 submitted 29 July, 2015; originally announced July 2015.

  12. Compressive Deconvolution in Medical Ultrasound Imaging

    Authors: Zhouye Chen, Adrian Basarab, Denis Kouamé

    Abstract: The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissions. Nevertheless, RF image spatial resolution, contrast and signal to noise ratio… ▽ More

    Submitted 4 December, 2015; v1 submitted 1 July, 2015; originally announced July 2015.

  13. arXiv:1412.2813  [pdf, other

    cs.CV

    Joint Segmentation and Deconvolution of Ultrasound Images Using a Hierarchical Bayesian Model based on Generalized Gaussian Priors

    Authors: Ningning Zhao, Adrian Basarab, Denis Kouame, Jean-Yves Tourneret

    Abstract: This paper proposes a joint segmentation and deconvolution Bayesian method for medical ultrasound (US) images. Contrary to piecewise homogeneous images, US images exhibit heavy characteristic speckle patterns correlated with the tissue structures. The generalized Gaussian distribution (GGD) has been shown to be one of the most relevant distributions for characterizing the speckle in US images. Thu… ▽ More

    Submitted 2 May, 2016; v1 submitted 8 December, 2014; originally announced December 2014.