-
Fast refacing of MR images with a generative neural network lowers re-identification risk and preserves volumetric consistency
Authors:
Nataliia Molchanova,
Bénédicte Maréchal,
Jean-Philippe Thiran,
Tobias Kober,
Till Huelnhagen,
Jonas Richiardi
Abstract:
With the rise of open data, identifiability of individuals based on 3D renderings obtained from routine structural magnetic resonance imaging (MRI) scans of the head has become a growing privacy concern. To protect subject privacy, several algorithms have been developed to de-identify imaging data using blurring, defacing or refacing. Completely removing facial structures provides the best re-iden…
▽ More
With the rise of open data, identifiability of individuals based on 3D renderings obtained from routine structural magnetic resonance imaging (MRI) scans of the head has become a growing privacy concern. To protect subject privacy, several algorithms have been developed to de-identify imaging data using blurring, defacing or refacing. Completely removing facial structures provides the best re-identification protection but can significantly impact post-processing steps, like brain morphometry. As an alternative, refacing methods that replace individual facial structures with generic templates have a lower effect on the geometry and intensity distribution of original scans, and are able to provide more consistent post-processing results by the price of higher re-identification risk and computational complexity. In the current study, we propose a novel method for anonymised face generation for defaced 3D T1-weighted scans based on a 3D conditional generative adversarial network. To evaluate the performance of the proposed de-identification tool, a comparative study was conducted between several existing defacing and refacing tools, with two different segmentation algorithms (FAST and Morphobox). The aim was to evaluate (i) impact on brain morphometry reproducibility, (ii) re-identification risk, (iii) balance between (i) and (ii), and (iv) the processing time. The proposed method takes 9 seconds for face generation and is suitable for recovering consistent post-processing results after defacing.
△ Less
Submitted 26 May, 2023;
originally announced May 2023.
-
Weakly Supervised Learning with Automated Labels from Radiology Reports for Glioma Change Detection
Authors:
Tommaso Di Noto,
Meritxell Bach Cuadra,
Chirine Atat,
Eduardo Gamito Teiga,
Monika Hegi,
Andreas Hottinger,
Patric Hagmann,
Jonas Richiardi
Abstract:
Gliomas are the most frequent primary brain tumors in adults. Glioma change detection aims at finding the relevant parts of the image that change over time. Although Deep Learning (DL) shows promising performances in similar change detection tasks, the creation of large annotated datasets represents a major bottleneck for supervised DL applications in radiology. To overcome this, we propose a comb…
▽ More
Gliomas are the most frequent primary brain tumors in adults. Glioma change detection aims at finding the relevant parts of the image that change over time. Although Deep Learning (DL) shows promising performances in similar change detection tasks, the creation of large annotated datasets represents a major bottleneck for supervised DL applications in radiology. To overcome this, we propose a combined use of weak labels (imprecise, but fast-to-create annotations) and Transfer Learning (TL). Specifically, we explore inductive TL, where source and target domains are identical, but tasks are different due to a label shift: our target labels are created manually by three radiologists, whereas our source weak labels are generated automatically from radiology reports via NLP. We frame knowledge transfer as hyperparameter optimization, thus avoiding heuristic choices that are frequent in related works. We investigate the relationship between model size and TL, comparing a low-capacity VGG with a higher-capacity ResNeXt model. We evaluate our models on 1693 T2-weighted magnetic resonance imaging difference maps created from 183 patients, by classifying them into stable or unstable according to tumor evolution. The weak labels extracted from radiology reports allowed us to increase dataset size more than 3-fold, and improve VGG classification results from 75% to 82% AUC. Mixed training from scratch led to higher performance than fine-tuning or feature extraction. To assess generalizability, we ran inference on an open dataset (BraTS-2015: 15 patients, 51 difference maps), reaching up to 76% AUC. Overall, results suggest that medical imaging problems may benefit from smaller models and different TL strategies with respect to computer vision datasets, and that report-generated weak labels are effective in improving model performances. Code, in-house dataset and BraTS labels are released.
△ Less
Submitted 26 January, 2023; v1 submitted 18 October, 2022;
originally announced October 2022.
-
The Multiscenario Multienvironment BioSecure Multimodal Database (BMDB)
Authors:
Javier Ortega-Garcia,
Julian Fierrez,
Fernando Alonso-Fernandez,
Javier Galbally,
Manuel R Freire,
Joaquin Gonzalez-Rodriguez,
Carmen Garcia-Mateo,
Jose-Luis Alba-Castro,
Elisardo Gonzalez-Agulla,
Enrique Otero-Muras,
Sonia Garcia-Salicetti,
Lorene Allano,
Bao Ly-Van,
Bernadette Dorizzi,
Josef Kittler,
Thirimachos Bourlai,
Norman Poh,
Farzin Deravi,
Ming NR Ng,
Michael Fairhurst,
Jean Hennebert,
Andreas Humm,
Massimo Tistarelli,
Linda Brodo,
Jonas Richiardi
, et al. (7 additional authors not shown)
Abstract:
A new multimodal biometric database designed and acquired within the framework of the European BioSecure Network of Excellence is presented. It is comprised of more than 600 individuals acquired simultaneously in three scenarios: 1) over the Internet, 2) in an office environment with desktop PC, and 3) in indoor/outdoor environments with mobile portable hardware. The three scenarios include a comm…
▽ More
A new multimodal biometric database designed and acquired within the framework of the European BioSecure Network of Excellence is presented. It is comprised of more than 600 individuals acquired simultaneously in three scenarios: 1) over the Internet, 2) in an office environment with desktop PC, and 3) in indoor/outdoor environments with mobile portable hardware. The three scenarios include a common part of audio/video data. Also, signature and fingerprint data have been acquired both with desktop PC and mobile portable hardware. Additionally, hand and iris data were acquired in the second scenario using desktop PC. Acquisition has been conducted by 11 European institutions. Additional features of the BioSecure Multimodal Database (BMDB) are: two acquisition sessions, several sensors in certain modalities, balanced gender and age distributions, multimodal realistic scenarios with simple and quick tasks per modality, cross-European diversity, availability of demographic data, and compatibility with other multimodal databases. The novel acquisition conditions of the BMDB allow us to perform new challenging research and evaluation of either monomodal or multimodal biometric systems, as in the recent BioSecure Multimodal Evaluation campaign. A description of this campaign including baseline results of individual modalities from the new database is also given. The database is expected to be available for research purposes through the BioSecure Association during 2008
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
Towards automated brain aneurysm detection in TOF-MRA: open data, weak labels, and anatomical knowledge
Authors:
Tommaso Di Noto,
Guillaume Marie,
Sebastien Tourbier,
Yasser Alemán-Gómez,
Oscar Esteban,
Guillaume Saliou,
Meritxell Bach Cuadra,
Patric Hagmann,
Jonas Richiardi
Abstract:
Brain aneurysm detection in Time-Of-Flight Magnetic Resonance Angiography (TOF-MRA) has undergone drastic improvements with the advent of Deep Learning (DL). However, performances of supervised DL models heavily rely on the quantity of labeled samples, which are extremely costly to obtain. Here, we present a DL model for aneurysm detection that overcomes the issue with ''weak'' labels: oversized a…
▽ More
Brain aneurysm detection in Time-Of-Flight Magnetic Resonance Angiography (TOF-MRA) has undergone drastic improvements with the advent of Deep Learning (DL). However, performances of supervised DL models heavily rely on the quantity of labeled samples, which are extremely costly to obtain. Here, we present a DL model for aneurysm detection that overcomes the issue with ''weak'' labels: oversized annotations which are considerably faster to create. Our weak labels resulted to be four times faster to generate than their voxel-wise counterparts. In addition, our model leverages prior anatomical knowledge by focusing only on plausible locations for aneurysm occurrence. We frst train and evaluate our model through cross-validation on an in-house TOF-MRA dataset comprising 284 subjects (170 females / 127 healthy controls / 157 patients with 198 aneurysms). On this dataset, our best model achieved a sensitivity of 83%, with False Positive (FP) rate of 0.8 per patient. To assess model generalizability, we then participated in a challenge for aneurysm detection with TOF-MRA data (93 patients, 20 controls, 125 aneurysms). On the public challenge, sensitivity was 68% (FP rate=2.5), ranking 4th/18 on the open leaderboard. We found no signifcant diference in sensitivity between aneurysm risk-of-rupture groups (p=0.75), locations (p=0.72), or sizes (p=0.15). Data, code and model weights are released under permissive licenses. We demonstrate that weak labels and anatomical knowledge can alleviate the necessity for prohibitively expensive voxel-wise annotations.
△ Less
Submitted 23 August, 2022; v1 submitted 10 March, 2021;
originally announced March 2021.
-
An anatomically-informed 3D CNN for brain aneurysm classification with weak labels
Authors:
Tommaso Di Noto,
Guillaume Marie,
Sébastien Tourbier,
Yasser Alemán-Gómez,
Guillaume Saliou,
Meritxell Bach Cuadra,
Patric Hagmann,
Jonas Richiardi
Abstract:
A commonly adopted approach to carry out detection tasks in medical imaging is to rely on an initial segmentation. However, this approach strongly depends on voxel-wise annotations which are repetitive and time-consuming to draw for medical experts. An interesting alternative to voxel-wise masks are so-called "weak" labels: these can either be coarse or oversized annotations that are less precise,…
▽ More
A commonly adopted approach to carry out detection tasks in medical imaging is to rely on an initial segmentation. However, this approach strongly depends on voxel-wise annotations which are repetitive and time-consuming to draw for medical experts. An interesting alternative to voxel-wise masks are so-called "weak" labels: these can either be coarse or oversized annotations that are less precise, but noticeably faster to create. In this work, we address the task of brain aneurysm detection as a patch-wise binary classification with weak labels, in contrast to related studies that rather use supervised segmentation methods and voxel-wise delineations. Our approach comes with the non-trivial challenge of the data set creation: as for most focal diseases, anomalous patches (with aneurysm) are outnumbered by those showing no anomaly, and the two classes usually have different spatial distributions. To tackle this frequent scenario of inherently imbalanced, spatially skewed data sets, we propose a novel, anatomically-driven approach by using a multi-scale and multi-input 3D Convolutional Neural Network (CNN). We apply our model to 214 subjects (83 patients, 131 controls) who underwent Time-Of-Flight Magnetic Resonance Angiography (TOF-MRA) and presented a total of 111 unruptured cerebral aneurysms. We compare two strategies for negative patch sampling that have an increasing level of difficulty for the network and we show how this choice can strongly affect the results. To assess whether the added spatial information helps improving performances, we compare our anatomically-informed CNN with a baseline, spatially-agnostic CNN. When considering the more realistic and challenging scenario including vessel-like negative patches, the former model attains the highest classification results (accuracy$\simeq$95\%, AUROC$\simeq$0.95, AUPR$\simeq$0.71), thus outperforming the baseline.
△ Less
Submitted 27 November, 2020;
originally announced December 2020.
-
Shallow vs deep learning architectures for white matter lesion segmentation in the early stages of multiple sclerosis
Authors:
Francesco La Rosa,
Mário João Fartaria,
Tobias Kober,
Jonas Richiardi,
Cristina Granziera,
Jean-Philippe Thiran,
Meritxell Bach Cuadra
Abstract:
In this work, we present a comparison of a shallow and a deep learning architecture for the automated segmentation of white matter lesions in MR images of multiple sclerosis patients. In particular, we train and test both methods on early stage disease patients, to verify their performance in challenging conditions, more similar to a clinical setting than what is typically provided in multiple scl…
▽ More
In this work, we present a comparison of a shallow and a deep learning architecture for the automated segmentation of white matter lesions in MR images of multiple sclerosis patients. In particular, we train and test both methods on early stage disease patients, to verify their performance in challenging conditions, more similar to a clinical setting than what is typically provided in multiple sclerosis segmentation challenges. Furthermore, we evaluate a prototype naive combination of the two methods, which refines the final segmentation. All methods were trained on 32 patients, and the evaluation was performed on a pure test set of 73 cases. Results show low lesion-wise false positives (30%) for the deep learning architecture, whereas the shallow architecture yields the best Dice coefficient (63%) and volume difference (19%). Combining both shallow and deep architectures further improves the lesion-wise metrics (69% and 26% lesion-wise true and false positive rate, respectively).
△ Less
Submitted 10 September, 2018;
originally announced September 2018.